TAMAQUA, PA —
OSHA Inspection: REMALY MANUFACTURING CO. INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of REMALY MANUFACTURING CO. INC. in 211 CEDAR ST., TAMAQUA, PA 18252 (NAICS 332710). OSHA activity number 342547981.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REMALY MANUFACTURING CO. INC.
- Site address
- 211 CEDAR ST.
- City
- TAMAQUA
- State
- PA
- ZIP
- 18252
- Mailing
- 211 CEDAR ST., TAMAQUA, PA 18252
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- Sep 12, 2017
- Abate by
- Oct 30, 2017
- Penalty
- Initial $2,078 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Main production area: Roll bending machines (2) were not guarded to protect the operator and other employees from hazards created by ingoing nip points of the rollers, as observed on or about August 15, 2017. Abatement Certification Required.
Recent events (2)
- — I (S) $1250
- — Z (S) $2078
1910.219 F03
- Issued
- Sep 12, 2017
- Abate by
- Oct 30, 2017
- Penalty
- Initial $2,078 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) Production area: The power transmission chain and sprockets on the Hills & Sons roll bending machine were not enclosed, as observed on or about August 15, 2017. Abatement Certification Required.
Recent events (2)
- — I (S) $1250
- — Z (S) $2078
1910.219 D01
- Issued
- Sep 12, 2017
- Abate by
- Oct 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Production area: The power transmission pulley at the rear of the Bliss mechanical power press was not guarded, as observed on or about August 15, 2017. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A03
- Issued
- Sep 12, 2017
- Abate by
- Oct 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(3): Walking-working surfaces were not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice: a) Production area: There was poor housekeeping of cutting and hydraulic fluids on the floor surrounding the leveling roller machine and presses, as observed on or about August 15, 2017. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 II
- Issued
- Sep 12, 2017
- Abate by
- Oct 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) Production area: The employer did not certify that periodic inspections of the energy control procedures for equipment including, but not limited to, mechanical power presses and roll bending machines had been performed, on or about August 15, 2017. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Sep 12, 2017
- Abate by
- Oct 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Boiler room and production area (welding): Sufficient access and working space was not maintained about all electric equipment including, but not limited to, panel and switch boxes and electrical disconnects to permit ready and safe operation, as observed on or about August 15, 2017. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Remaly Manufacturing CO. INC.
View Remaly Manufacturing CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342547981.