NEW YORK, NY —
OSHA Inspection: APOLLO TECH IRON WORKS
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of APOLLO TECH IRON WORKS in 106 SOUTH STREET, NEW YORK, NY 10038 (NAICS 238120). OSHA activity number 342548435.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APOLLO TECH IRON WORKS
- Site address
- 106 SOUTH STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10038
- Mailing
- 170 VAN BRUNT STREET, BROOKLYN, NY 11231
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.300 B01
- Issued
- Jan 31, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) On or about 8/9/17 at a rehabilitation project located at 106 South Street, New York, New York; an employee was using an angle grinder to clean, cut and prepare steel sections while welding. There was no guard on the grinder. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $3880
1926.350 A07
- Issued
- Jan 31, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.350(a)(7): A suitable cylinder truck, chain, or other steadying device was not used to keep compressed gas cylinder(s) from being knocked over while in use: a) On or about 8/9/17 at a rehabilitation project located at 106 South Street, New York, New York; on the first floor against the sidewalk enclosure, an oxygen cylinder and an acetylene cylinder were placed next to the wall and were not secured against tipping or displacement. NO ABATEMENT CERTIRFICATION REQUIRED
Recent events (1)
- — Z (S) $3880
1926.502 B01
- Issued
- Jan 31, 2018
- Penalty
- Initial $6,467 · Current $6,467
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a) On or about 8/9/17 at a renovation project located at 106 South Street, New York, New York; guardrail systems through out the project had improper toprail heights that varied between 21" and 37". The guardrails were intended to protect stairwells, an elevator shaft, utility shafts, and the roofs edge. employees were exposed to falls of more than 40 feet. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $6467