Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AERIAL PRECAST CONCRETE, LLC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AERIAL PRECAST CONCRETE, LLC. in 3100 BURRIS ROAD, DAVIE, FL 33314 (NAICS 327390). OSHA activity number 342549078.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aerial Precast Concrete, LLC. — free Get an email when a new federal OSHA severe-injury report for Aerial Precast Concrete, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
3100 BURRIS ROAD
City
DAVIE
State
FL
ZIP
33314
Mailing
3100 BURRIS ROAD, DAVIE, FL 33314
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
35
Ownership type
A

3 citations on file for this inspection.

1910.134 C02 II

Other-than-serious 1 instance 5 exposed
Issued
Jan 29, 2018
Abate by
Feb 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:   On or about August 15, 2017, at the above addressed jobsite, the employer did not establish a written program for employees who voluntarily wear tight fitting elastomeric respirators during welding operations.
Recent events (1)
  • — Z (O) $0

1910.134 K06

Other-than-serious 1 instance 5 exposed
Issued
Jan 29, 2018
Abate by
Feb 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The basic advisory information on respirators, as presented in Appendix D of this section, shall be provided by the employer in any written or oral format, to employees who wear respirators when such use is not required by this section or by the employer.  On or about August 15, 2017, at the above addressed jobsite, the employer did not ensure that employees who voluntarily use filtering facepiece respirators during painting and welding operations, were provided with information contained in Appendix D.
Recent events (1)
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 5 exposed
Issued
Jan 29, 2018
Abate by
Mar 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  On or about August 15, 2017, at the above addressed jobsite, the employer did not develop a written hazard program for employees who generate manganese fume, iron oxide, and copper fume,  during welding; use oxygen and acetylene for torch cutting; and use mineral spirits for coating operation.
Recent events (1)
  • — Z (O) $0

View Aerial Precast Concrete, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342549078.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.