WHITESTONE, NY —
OSHA Inspection: SHENG SHENG CONSTRUCTION INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SHENG SHENG CONSTRUCTION INC. in 148-11 15TH AVE, WHITESTONE, NY 11357 (NAICS 238910). OSHA activity number 342549128.
Where did this inspection happen?
- Establishment
- SHENG SHENG CONSTRUCTION INC.
- Site address
- 148-11 15TH AVE
- City
- WHITESTONE
- State
- NY
- ZIP
- 11357
- Mailing
- 17-17 166TH STREET, WHITESTONE, NY 11357
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $3049.00 · Current $1950.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): 1) On or about 8/15/2017, at the site of 148-11 15th Ave. Whitestone, NY Employees demolishing a steep roof with the ratio of 6 in 12 was exposed to the hazard of falling approximately 27 ft. to the ground below. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
- — I (S) $1950
- — Z (S) $3049
1926.1053 B04
- Issued
- Penalty
- Initial $3049.00 · Current $1950.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: 1) On or about 8/15/2017, at the site of 148-11 15th Ave. Whitestone, NY Employees used an A-frame ladder as a straight ladder to access a steep roof, 13-feet above lower level, while performing demolition work. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
- — I (S) $1950
- — Z (S) $3049
More inspections at SHENG SHENG CONSTRUCTION INC.
WHITESTONE, NY—2017-08-15 00:00:00
SHENG SHENG CONSTRUCTION INC.
FOREST HILLS, NY—2015-12-31 00:00:00
SHENG SHENG CONSTRUCTION INC.
LITTLE NECK, NY—2012-07-30 00:00:00
SHENG SHENG CONSTRUCTION INC.
View SHENG SHENG CONSTRUCTION INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
SIOUX FALLS, SD—2026-07-10
SOUKUP CONSTRUCTION, INC.
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
BAKERSFIELD, CA—2026-07-10
BENCHMARK PIPELINE INC.
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
AMERICAN CANYON, CA—2026-07-10
ENVIRONCARE INTERNATIONAL
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source