Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: KANAWHA VALLEY SIDING AND WINDOW, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KANAWHA VALLEY SIDING AND WINDOW, INC. in 4416 NOYES AVENUE, CHARLESTON, WV 25304 (NAICS 238170). OSHA activity number 342551611.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kanawha Valley Siding and Window, INC. for free Get an email when a new federal OSHA severe-injury report for Kanawha Valley Siding and Window, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4416 NOYES AVENUE
City
CHARLESTON
State
WV
ZIP
25304
Mailing
PO BOX 13367, CHARLESTON, WV 25360
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 B03

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 21, 2017
Abate by
Oct 18, 2017
Penalty
Initial $1,630 · Current $1,630
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling.  a.)  4416 Noyes Avenue, Charleston WV:  On or about 08/16/17, the front edge of the platform of the pump jack scaffold was 25" from the face of the building.
Recent events (1)
  • · Z (S) $1630

1926.452 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2017
Abate by
Oct 18, 2017
Penalty
Initial $2,173 · Current $2,173
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  a.)  4416 Noyes Avenue, Charleston WV:  On or about 08/16/17, the pump jack scaffold used to install siding on the residential home was not secured at the bottom.
Recent events (1)
  • · Z (S) $2173

View Kanawha Valley Siding and Window, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342551611.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.