CHARLESTON, WV ·
OSHA Inspection: KANAWHA VALLEY SIDING AND WINDOW, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KANAWHA VALLEY SIDING AND WINDOW, INC. in 4416 NOYES AVENUE, CHARLESTON, WV 25304 (NAICS 238170). OSHA activity number 342551611.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KANAWHA VALLEY SIDING AND WINDOW, INC.
- Site address
- 4416 NOYES AVENUE
- City
- CHARLESTON
- State
- WV
- ZIP
- 25304
- Mailing
- PO BOX 13367, CHARLESTON, WV 25360
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.451 B03
- Issued
- Sep 21, 2017
- Abate by
- Oct 18, 2017
- Penalty
- Initial $1,630 · Current $1,630
General-duty citation text
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling. a.) 4416 Noyes Avenue, Charleston WV: On or about 08/16/17, the front edge of the platform of the pump jack scaffold was 25" from the face of the building.
Recent events (1)
- · Z (S) $1630
1926.452 J02
- Issued
- Sep 21, 2017
- Abate by
- Oct 18, 2017
- Penalty
- Initial $2,173 · Current $2,173
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a.) 4416 Noyes Avenue, Charleston WV: On or about 08/16/17, the pump jack scaffold used to install siding on the residential home was not secured at the bottom.
Recent events (1)
- · Z (S) $2173
More inspections at Kanawha Valley Siding and Window, INC.