On , OSHA opened a programmed Related safety inspection of DAVCO ELECTRICAL CONTRACTORS CORP. in 115 AVE OF THE ARTS, FORT LAUDERDALE, FL 33312 (NAICS 238210). OSHA activity number 342551900.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAVCO ELECTRICAL CONTRACTORS CORP.
- Site address
- 115 AVE OF THE ARTS
- City
- FORT LAUDERDALE
- State
- FL
- ZIP
- 33312
- Mailing
- 4885 PARK RIDGE BLVD., BOYNTON BEACH, FL 33426
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 266
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.140 C22
- Issued
- Dec 19, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $12,675 · Current $6,338 Reduced
General-duty citation text
29 CFR 1910.140(c)(22): Personal fall protection systems were not worn with the attachment point of the body harness located in the center of the employee's back near shoulder level. The attachment point may be located in the pre-sternal position if the free fall distance is limited to 2 feet (0.6 m) or less: On or about August 11, 2017, at the above addressed jobsite, employees were performing maintenance/repairs on street lights (replacing bulbs/worn out fixtures) from the basket of an aerial lift, wherein the employee was wearing a personal fall arrest system that did not meet the requirements in subpart I of this part, therefore exposing the employees to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $6338
- — Z (S) $12675
1910.30 A03 III
- Issued
- Dec 19, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.30(a)(3)(iii): The employer did not train each employee in the correct procedures for installing, inspecting, operating, maintaining, and disassembling the personal fall protection systems that the employee used: On or about August 11, 2017, at the above addressed jobsite, employees were performing maintenance/repairs on street lights (replacing bulbs/worn out fixtures) from the basket of an aerial lift, during which the employer did not provide training to each employee who is required by this section to use PPE, and wherein the employee was using PPE (PFAS), therefore exposing the employees to a fall hazard and/or suspension trauma/orthostatic shock hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.132 D01 III
- Issued
- Dec 19, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $12,675 · Current $6,338 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(iii): The employer did not select PPE that properly fit each affected employee: On or about August 11, 2017, at the above addressed jobsite, employees were performing maintenance/repairs on street lights (replacing bulbs/worn out fixtures) from the basket of an aerial lift, during which the employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitate the use of personal protective equipment (PPE), and wherein the employee was performing the aforementioned work activities with PPE (PFAS), therefore exposing the employees to a fall hazard and/or suspension trauma/orthostatic shock hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $6338
- — Z (S) $12675
1910.132 D02
- Issued
- Dec 19, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: On or about August 11, 2017, at the above addressed jobsite, employees were performing maintenance/repairs on street lights (replacing bulbs/worn out fixtures) from the basket of an aerial lift, during which the employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment; and wherein the employee was performing the aforementioned work activities with PPE (PFAS), therefore exposing the employees to a fall hazard and/or suspension trauma/orthostatic shock hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Davco Electrical Contractors Corp.
View Davco Electrical Contractors Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342551900.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.