OCEAN CITY, NJ ·
OSHA Inspection: LEONARDO LOPEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LEONARDO LOPEZ in 3041 CENTRAL AVE, OCEAN CITY, NJ 08226 (NAICS 238130). OSHA activity number 342552403.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEONARDO LOPEZ
- Site address
- 3041 CENTRAL AVE
- City
- OCEAN CITY
- State
- NJ
- ZIP
- 08226
- Mailing
- 24 RIDGE AVE, BRIDGETON, NJ 08302
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 E01
- Issued
- Jan 19, 2018
- Abate by
- Jan 25, 2018
- Penalty
- Initial $3,880 · Current $1,228 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: A) Construction site, 3041 Central Ave, Ocean City, NJ: Employees did not have a proper means of accessing the aluminum scaffold pick approximately 6 feet above the 1st floor deck, on or about 08/16/2017. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1228
- · Z (S) $3880
1926.451 G01
- Issued
- Jan 19, 2018
- Abate by
- Jan 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: A) 2nd level of a 3 story home under construction; 3041 Central Ave, Ocean City, NJ: Employees without any type of fall protection were working at the edges of the upper levels between approximately 10-19 feet above ground level, on or about 08/16/2017. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B01
- Issued
- Jan 19, 2018
- Penalty
- Initial $2,772 · Current $2,772
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS) a) West side: The Werner Model D 1220-2 Aluminum Extension ladder extended approximately 12-14 inches above the 1st floor level (approximately 12 feet above ground level) being accessed by employees, on or about 08/16/2017. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- · I (S) $2772
- · Z (S) $2772
1926.1053 B15
- Issued
- Jan 19, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: a) West side, north corner of structure: Employees used the damaged Werner Model D 1220-2 Aluminum Extension ladder to access the approximate 10 foot high 1st floor level; damage included bottom right shoe bent in towards the middle of the ladder, on or about 08/16/2017. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1051 A
- Issued
- Jan 19, 2018
- Abate by
- Jan 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) Southwest corner, 2nd floor: Employees hopped approximately 3 feet down from the 2nd floor to an aluminum scaffold pick, then another approximate 6 feet to the 1st floor level, on or about 08/16/2017. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238130)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342552403.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.