EL PASO, TX —
OSHA Inspection: REY CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of REY CONSTRUCTION in 6573 MCFARLAND AVE., EL PASO, TX 79932 (NAICS 238130). OSHA activity number 342552494.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REY CONSTRUCTION
- Site address
- 6573 MCFARLAND AVE.
- City
- EL PASO
- State
- TX
- ZIP
- 79932
- Mailing
- 635 MESA VIEW, CHAPARRAL, NM 88081
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.25 A
- Issued
- Oct 18, 2017
- Abate by
- Nov 6, 2017
- Penalty
- Initial $1,793 · Current $1,793
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form or scrap lumber with protruding nails was not kept clear from work areas: On or about august 14, 2017, employees were working on the construction of a residential home. The jobsite was littered with rocks, debris and unused lumber. It was also observed that some of the pieces of unused wood had protruding nails on them. These conditions created not only a trip hazard for employees but a puncture hazard as well.
Recent events (1)
- — Z (S) $1793
1926.403 B01 III
- Issued
- Oct 18, 2017
- Abate by
- Nov 6, 2017
- Penalty
- Initial $1,793 · Current $1,793
General-duty citation text
29 CFR 1926.403(b)(1)(iii): The employer did not ensure that electrical equipment was free from recognized hazards that are likely to cause death or serious physical harm to employees; sections of the electrical insulation on cords and cables was missing: On or about August 14, 2017, employees were working on the construction of a residential home. They were using at least three extension cords that had damage to their insulation. This exposed the employees to electric shock hazards.
Recent events (1)
- — Z (S) $1793
1926.404 B01 III C
- Issued
- Oct 18, 2017
- Abate by
- Nov 6, 2017
- Penalty
- Initial $1,793 · Current $1,793
General-duty citation text
29 CFR 1926.404(b)(1)(iii)(C): The employer did not ensure that each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage: On or about August 14, 2017, employees were working on the construction of a residential home. They were using an extension cord that was missing the ground pin to power a Dewalt circular saw.
Recent events (1)
- — Z (S) $1793
1926.501 B13
- Issued
- Oct 18, 2017
- Abate by
- Nov 6, 2017
- Penalty
- Initial $2,390 · Current $2,390
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net systems or personal fall arrest systems: On or about august 14, 2017, employees were working on the construction of a residential home. Two employees were observed working on the framework of the home without any form of fall protection. The employees were exposed to fall hazards of greater than six feet to the ground below.
Recent events (1)
- — Z (S) $2390
1926.503 A01
- Issued
- Oct 18, 2017
- Abate by
- Nov 6, 2017
- Penalty
- Initial $1,793 · Current $1,793
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not train each employee who might be exposed to fall hazards to enable them to recognize fall hazards and the procedures to be followed in order to minimize these hazards: On or about August 14, 2017, the employer did not provide a fall protection training program to employees. Employees were exposed to fall hazards of more than six feet.
Recent events (1)
- — Z (S) $1793
More inspections at REY Construction
View REY Construction's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342552494.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.