MUNDELEIN, IL ·
OSHA Inspection: AGRIFIBER SOLUTIONS LLC
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of AGRIFIBER SOLUTIONS LLC in 1011 CAMPUS DRIVE, MUNDELEIN, IL 60060 (NAICS 311999). OSHA activity number 342554565.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AGRIFIBER SOLUTIONS LLC
- Site address
- 1011 CAMPUS DRIVE
- City
- MUNDELEIN
- State
- IL
- ZIP
- 60060
- Mailing
- 1011 CAMPUS DRIVE, MUNDELEIN, IL 60060
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 13
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Sep 22, 2017
- Penalty
- Initial $2,897 · Current $2,897
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Shop - On August 16, 2017, the employer failed to ensure that a method of guarding was used to protect employees from the rotating chuck on the Grizzly Serial# 832273 lathe during operation. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $2897
1910.147 C06 II
- Issued
- Sep 22, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) Facility Wide - On August 16, 2017, the employer did not certify that periodic inspections of the energy control procedures were performed and contained the required documentation such as the identification of the machine or equipment, inspection date, employees included and the person performing the inspection. No abatement certification or documentation is required for this item.