Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTHEAST CARTAGE, L.L.C.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORTHEAST CARTAGE, L.L.C. in 50 BREAKER ROAD, HANOVER TOWNSHIP, PA 18706 (NAICS 423930). OSHA activity number 342554581.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northeast Cartage, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Northeast Cartage, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
50 BREAKER ROAD
City
HANOVER TOWNSHIP
State
PA
ZIP
18706
Mailing
P.O. BOX 1474, KINGSTON, PA 18704
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
47
Ownership type
A

2 citations on file for this inspection.

1910.242 B

Serious Gravity 1 1 instance 30 exposed
Issued
Dec 29, 2017
Abate by
Jan 26, 2018
Penalty
Initial $3,802 · Current $2,852 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a) Facility, 50 Breaker Road, Hanover Township (Wilkes-Barre), PA - Employees used wands that emitted compressed air with a gauge pressure greater than ninety pounds per square inch (>90 p.s.i.) to clean debris (plastic, metal, paper, etc.) from the floor, forklifts, and balers. Employees were exposed to potential injury caused by high pressure air, as observed on August 16, 2017.  In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (S) $2851.5
  • — Z (S) $3802

1910.147 C06 I

Other-than-serious 1 instance 30 exposed
Issued
Dec 29, 2017
Abate by
Jan 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.  a) Facility, 50 Breaker Road, Hanover Township (Wilkes-Barre) PA - Periodic inspections, at least annually, of the energy control procedures utilized by employees prior to the performance of service and maintenance for equipment such as but not limited to the balers, conveyors, compressor, and the separation line equipment were not conducted exposing employees to the unexpected release of energy in the event of equipment modifications or new equipment, on or about August 16, 2017.  In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Northeast Cartage, L.L.C.'s full OSHA safety record →