AUBURN, WA ·
OSHA Inspection: FEDERAL AVIATION ADMINISTRATION, SEATTLE AIR ROUTE TRAFFIC CONTROL CENTER
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FEDERAL AVIATION ADMINISTRATION, SEATTLE AIR ROUTE TRAFFIC CONTROL CENTER in 3101 AUBURN WAY SOUTH, AUBURN, WA 98092 (NAICS 926120). OSHA activity number 342562386.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 3101 AUBURN WAY SOUTH
- City
- AUBURN
- State
- WA
- ZIP
- 98092
- Mailing
- 3101 AUBURN WAY SOUTH, AUBURN, WA 98092
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 926120
- Employees
- 450
- Ownership type
- Federal government (D)
Citations
7 citations on file for this inspection.
1910.213 S06
- Issued
- Sep 25, 2017
- Abate by
- Oct 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards: a) Garage/Carpenter Shop. A Ridgid miter saw and a Rockwell Drill Press had sawdust around the equipment. This exposes employees to potential fire hazards and ineffective guarding.
Recent events (1)
- · Z (S) $0
1910.303 B02
- Issued
- Sep 25, 2017
- Abate by
- Oct 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Air Traffic Control A Area; A Proctor Silex toaster oven and Hamilton Beach kettle were plugged into a surge protector (relocatable power tap). The UL listing states that relocatable power taps are designed for low amperage computer and audiovisual types of equipment, and not appliances. This exposes employees to possible electrical fire hazards. CORRECTED DURING INSPECTION b) Garage Office; A Sharp microwave and Frigidaire refrigerator were plugged into a surge protector (relocatable power tap). The UL listing states that relocatable power taps are designed for low amperage computer and audiovisual types of equipment, and not appliances. This exposes employees to possible electrical fire hazards.
Recent events (1)
- · Z (S) $0
1910.305 G01 IV A
- Issued
- Sep 25, 2017
- Abate by
- Oct 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Air Traffic Control B Area; A Keurig was plugged into an extension cord. b) Air Traffic Control B Area; A Magic Chef microwave was plugged into an extension cord.
Recent events (1)
- · Z (S) $0
1910.1025 H01
- Issued
- Sep 25, 2017
- Abate by
- Oct 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead: a) COM Maintenance Room B101; There was surface lead contamination on the countertop with the soldering equipment. This exposes employees to lead ingestion hazards. *Please note that surfaces (other than glass or metal) are porous and gritty scrubbing cleaners (examples are Soft Scrub, Comet or Ajax) are sometimes needed to fully decontaminate the area from surface lead contamination.
Recent events (1)
- · Z (S) $0
1910.145 C02 I
- Issued
- Sep 25, 2017
- Abate by
- Oct 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices: a) COM Maintenance Room B101; Caution signs were not posted to alert employees of the presence of lead and the precautions to take while soldering with lead containing solder. This exposes employees to potential lead ingestion hazards.
Recent events (1)
- · Z (S) $0
1910.1200 F06 II
- Issued
- Sep 25, 2017
- Abate by
- Oct 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: a) Generator Room; A large container of antifreeze was not labeled. b) Chiller Room; A white spray bottle with a cleaning chemical was not labeled. This exposes employees to respiratory irritation and/or dermatitis hazards.
Recent events (1)
- · Z (S) $0
1910.1200 G01
- Issued
- Sep 25, 2017
- Abate by
- Oct 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: a) Garage/ Welding Area; The Forney Mild Steel Migwire did not have a safety data sheet. b) Room B101, COM Area; The LB Allen Co. Soldering Flux, and Kester lead containing solder did not have a safety data sheet. c) Room 110F, Automation Maintenance; The LB Allen Co. Soldering Flux did not have a safety data sheet. This exposes employees to possible respiratory irritation and or dermatitis hazards.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 926120)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342562386.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.