OSHA Inspection: PARALLEL PRODUCTS OF COLORADO, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PARALLEL PRODUCTS OF COLORADO, LLC in 123 9TH AVENUE, GREELEY, CO 80631 (NAICS 331312). OSHA activity number 342563871.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Parallel Products of Colorado, LLC for free Get an email when a new federal OSHA severe-injury report for Parallel Products of Colorado, LLC is published. One employer, no account, unsubscribe in one click.
Site address
123 9TH AVENUE
City
GREELEY
State
CO
ZIP
80631
Mailing
123 9TH AVENUE, GREELEY, CO 80631
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331312
Employees
25
Ownership type
Private (A)

5 citations on file for this inspection.

1910.23 C08

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 1, 2017
Abate by
Nov 29, 2017
Penalty
Initial $7,243 · Current $4,000 Reduced
29 CFR 1910.23(c)(8):  The employer did not ensure that the top cap and the top step of a step ladder were not used as steps:    (a)  Parallel Products of Colorado, LLC at 123 9th Ave , Greeley, CO 80631:  On and before August 18, 2017, the employer allowed employees to use the top step of a stepladder as a step.  Employees used the top step of a 6 foot stepladder as a step to grease the auger.  This condition exposed the employees to fall hazards of up to approximately 5 feet.
Recent events (2)
  • · I (S) $4000
  • · Z (S) $7243

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 1, 2017
Abate by
Nov 29, 2017
Penalty
Initial $9,054 · Current $5,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a)  Parallel Products of Colorado, LLC at 123 9th Ave., Greeley, CO 80631:  On and before August 18, 2017, the employer did not ensure that specific procedural steps were developed, documented, and utilized for shutting down and isolating hazardous energy for equipment such as, but not limited to, the baler, auger and can crusher.  An employee participated in greasing the upper part of the auger by climbing up on the adjacent baler, and standing on top of it.  The baler activated, and caught the employee's foot on the baler ejector chain, resulting in a partial amputation of the employee's foot.  This condition resulted in exposure to an amputation hazard.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $9054

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 1, 2017
Abate by
Dec 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:    (a)  Parallel Products of Colorado, LLC. at 123 9th Ave., Greeley, CO 80631:  On and before August 18, 2017, the employer did not ensure that a periodic inspection of the energy control procedures was conducted at least annually to ensure that the procedures and the requirements of this standard were being followed.  The employees performed greasing and maintenance on machines such as, but not limited to, the baler, the auger, and the can crusher, and the employer did not conduct inspections to ensure that energy control procedures were in place.  This condition resulted exposure to amputation hazards.     Abatement note:  29 CFR 1910.147(c)(6)(ii) provides that the employer shall certify that periodic inspections were performed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 1, 2017
Abate by
Nov 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees, and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees:  (a)  Parallel Products of Colorado, LLC at 123 9th Ave., Greeley, CO 80631:  On and before August 18, 2017, the employer did not ensure that training was provided to ensure the function and purpose of energy control procedures was understood and properly applied by employees.  The employer did not ensure that energy control training resulted recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  In addition, the energy control training did not ensure that employees understood that adjacent machinery also needed to be de-energized when employees were working in close proximity.  This condition exposed employees to amputation hazards.  Abatement note:  29 CFR 1910.147(c)(7)(iv) provides that the employer shall certify that employee training has been accomplished and is being kept up to date.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 1, 2017
Abate by
Nov 29, 2017
Penalty
Initial $9,054 · Current $5,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a)  Parallel Products of Colorado, LLC at 123 9th Ave., Greeley, CO 80631:  On and before August 18, 2017 the employer did not ensure that one or more methods of machine guarding was provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  The employer did not ensure that the baler was properly guarded around the baler ejector chain and at its point of operation.  This condition resulted in exposure to amputation hazards.