Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: NICHOLAS DEVELOPMENT, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NICHOLAS DEVELOPMENT, LLC in 4590 MCARTHUR BLVD., NW, WASHINGTON, DC 20007 (NAICS 236220). OSHA activity number 342563905.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nicholas Development, LLC for free Get an email when a new federal OSHA severe-injury report for Nicholas Development, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4590 MCARTHUR BLVD., NW
City
WASHINGTON
State
DC
ZIP
20007
Mailing
5290 SHAWNEE RD., ALEXANDRIA, VA 22312
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
8
Ownership type
Private (A)

4 citations on file for this inspection.

1926.451 C02 IV

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 8, 2018
Penalty
Initial $9,054 · Current $5,251 Reduced
29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use:      a)  Rear Parking Lot - On or about 08/17/2017, workers were exposed to a 20 foot fall hazard while working from a 4 foot by 8 foot job-made temporary work platform which was constructed by superintendent, Matt Boehrer, on the job site, the box was not specifically designed by the lift's manufacturer, and was elevated by a SKYTRAK Model: 6042, powered industrial truck.     No abatement certification or documentation required for this item.
Recent events (2)
  • · I (S) $5251
  • · Z (S) $9054

1926.451 C02 V

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 8, 2018
Penalty
Initial $9,054 · Current $5,251 Reduced
29 CFR 1926.451(c)(2)(v): Fork-lifts were used to support scaffold platforms while the entire platform was not attached to the fork and the fork-lift was moved horizontally while the platform was occupied:       a)  Rear Parking Lot - On or about 08/17/2017, workers were exposed to a 20 foot fall hazard while occupying an elevated 4 foot by 8 foot job-made temporary work platform which was moved horizontally and was not attached to the forks of a Skytrak Model 6042 (serial no. 0160052482) powered industrial truck.     No abatement certification or documentation required for this item.
Recent events (2)
  • · I (S) $5251
  • · Z (S) $9054

1926.451 G01

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 8, 2018
Penalty
Initial $9,054 · Current $5,251 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:     a)  Rear parking Lot - On or about August 17, 2017, three construction laborers were exposed to a 20 foot fall from a temporary work platform which had not been provided with standard guardrails to any alternative means of fall protection, including, but not limited to, personal fall protection, nets or similar effective means.     No abatement certification or documentation required for this item.
Recent events (2)
  • · I (S) $5251
  • · Z (S) $9054

1926.454 A

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 8, 2018
Abate by
Feb 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:   a)  Rear Parking Lot - On or about August 17, 2017, construction workers working from a temporary work platform elevated by a powered industrial truck were not provided with training by a qualified person.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342563905.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.