OSHA Inspection: LANFAIR BUILDING & REMODELING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LANFAIR BUILDING & REMODELING in 12336 EBRIGHT LANE, PICKERINGTON, OH 43147 (NAICS 238130). OSHA activity number 342565413.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lanfair Building & Remodeling — free Get an email when a new federal OSHA severe-injury report for Lanfair Building & Remodeling is published. One employer, no account, unsubscribe in one click.
Site address
12336 EBRIGHT LANE
City
PICKERINGTON
State
OH
ZIP
43147
Mailing
10424 RICH HOLLOW ROAD, LANCASTER, OH 43130
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Repeat Gravity 10 1 instance 3 exposed
Issued
Aug 29, 2017
Abate by
Sep 8, 2017
Penalty
Initial $8,366 · Current $4,183 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a. On or about August 22, 2017, employees were installing sheathing on the roof of the house without fall protection, thereby exposing employees to a fall hazard of approximately twenty foot.  Lanfair Building & Remodeling was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 1097471, citation number 1, item number 2 and was affirmed as a final order on 11/25/2015 with respect to a workplace located at 3903 Mad River Road/Lot 225 in Grove City, OH 43123.
Recent events (2)
  • — I (R) $4183
  • — Z (R) $8366

View Lanfair Building & Remodeling's full OSHA safety record →