IRVING, TX —
OSHA Inspection: MANUEL ALEXANDER CANALES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MANUEL ALEXANDER CANALES in 415 RENAISSANCE, IRVING, TX 75060 (NAICS 238140). OSHA activity number 342573052.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANUEL ALEXANDER CANALES
- Site address
- 415 RENAISSANCE
- City
- IRVING
- State
- TX
- ZIP
- 75060
- Mailing
- 2002 ROCKISLAND RD APT #1056, IRVING, TX 75060
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Oct 19, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $3,803 · Current $1,900 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (a) On August 22, 2017 Employees were exposed to a fall hazard of approximately 12 feet in height while working on a 3 tier scaffold with missing planks.
Recent events (2)
- — I (S) $1900
- — Z (S) $3803
1926.451 E01
- Issued
- Oct 19, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $3,803 · Current $1,900 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. (a) On August 22, 2017 Employees were exposed to a fall hazard of approximately 12 feet in height while working on a 3 tier scaffold and using cross braces as means of access and egress.
Recent events (2)
- — I (S) $1900
- — Z (S) $3803
1926.451 G04 I
- Issued
- Oct 19, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $3,803 · Current $1,900 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. (a)On August 22, 2017 Employees were exposed to a fall hazard of approximately 12 feet in height while working on a 3 tier scaffold without guard rails on the open ends.
Recent events (2)
- — I (S) $1900
- — Z (S) $3803
1926.451 H01
- Issued
- Oct 19, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $1,630 · Current $950 Reduced
General-duty citation text
29 CFR 1926.451(h)(1): In addition to wearing hardhats each employee on a scaffold shall be provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, or guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. When the falling objects are too large, heavy or massive to be contained or deflected by any of the above-listed measures, the employer shall place such potential falling objects away from the edge of the surface from which they could fall and shall secure those materials as necessary to prevent their falling. (a) On August 22, 2017 Employees were exposed to a struck by hazard from bricks placed above them on the scaffold without the use of toe boards .
Recent events (2)
- — I (S) $950
- — Z (S) $1630
1926.452 C02
- Issued
- Oct 19, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $2,173 · Current $950 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. On August 22, 2017 employees were exposed to fall from structural instability by missing a cross brace section of the 3 tier scaffold.
Recent events (2)
- — I (S) $950
- — Z (S) $2173
More inspections at Manuel Alexander Canales
View Manuel Alexander Canales's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342573052.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.