HIALEAH, FL ·
OSHA Inspection: RIOS WIRE LATH LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIOS WIRE LATH LLC in 15400 NW 97TH AVENUE BLDG 36 / LOT 15, HIALEAH, FL 33018 (NAICS 238910). OSHA activity number 342573102.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIOS WIRE LATH LLC
- Site address
- 15400 NW 97TH AVENUE BLDG 36 / LOT 15
- City
- HIALEAH
- State
- FL
- ZIP
- 33018
- Mailing
- 8964 W. FLAGLER STREET SUITE 112, MIAMI, FL 33174
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Dec 11, 2017
- Penalty
- Initial $2,716 · Current $1,358 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 8/16/2017, at the above addressed worksite, employees were exposed to fall hazards while installing corner beams on a residential townhouse from a two-tier scaffold that was not fully planked.
Recent events (2)
- · I (S) $1358
- · Z (S) $2716
1926.451 F03
- Issued
- Dec 11, 2017
- Abate by
- Jan 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about 8/16/2017, at the above addressed worksite, the employer did not inspect the scaffold before each work shift, which the scaffold had missing planks, guardrails, and no access ladder for employees to climb up and down the scaffold. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 E01
- Issued
- Dec 11, 2017
- Penalty
- Initial $2,716 · Current $1,358 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 8/16/2017, at the above addressed worksite, employees were exposed to fall hazards while installing corner beams on a residential townhouse from a two-tier scaffold that lack access to the 2nd tier.
Recent events (2)
- · I (S) $1358
- · Z (S) $2716
1926.451 G01 VII
- Issued
- Dec 11, 2017
- Penalty
- Initial $2,716 · Current $1,358 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about 8/16/2017, at the above addressed worksite, employees were exposed to fall hazards while installing corner beams on a residential townhouse from a two-tier scaffold that lack guardrails.
Recent events (2)
- · I (S) $1358
- · Z (S) $2716
1926.451 G04 I
- Issued
- Dec 11, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: On or about 8/16/2017, at the above addressed worksite, employees were exposed to fall hazards while installing corner beams on a residential townhouse from a two-tier scaffold that lack guardrails along open sides and ends of platforms.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238910)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342573102.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.