OSHA Inspection: ADVANCED POWER & LIGHTING, LLC

Fatality or catastrophe inspection · Safety discipline

On , OSHA opened a fatality or catastrophe safety inspection of ADVANCED POWER & LIGHTING, LLC in 1022 COUNTY ROAD 768, CULLMAN, AL 35055 (NAICS 237130). OSHA activity number 342581816.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Power & Lighting, LLC for free Get an email when a new federal OSHA severe-injury report for Advanced Power & Lighting, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1022 COUNTY ROAD 768
City
CULLMAN
State
AL
ZIP
35055
Mailing
6117 DAYTON BLVD. SUITE A, HIXSON, TN 37343
Inspection type
Fatality or catastrophe (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

1926.952 A02

Other-than-serious 1 instance 1 exposed
Issued
Nov 17, 2017
Abate by
Oct 9, 2018
Penalty
Initial $8,873 · Current $8,873
29 CFR 1926.952(a)(2): The employer did not ensure the employee in charge conducted a job briefing that met paragraphs (b), (c), and (d) of this section with the employees involved before they started each job:    (a) On or about 08/22/2017 - 1022 County Road 768, Cullman, AL, a job briefing was not conducted for employees replacing power line pole pin insulators.
Recent events (3)
  • · J (O) $8873
  • · C (S) $8873
  • · Z (S) $8873

1926.960 C01 III

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Nov 17, 2017
Abate by
Nov 30, 2017
Penalty
Initial $12,675 · Current $0 Reduced
29 CFR 1926.960(c)(1)(iii): The employer did not ensure that employees would not approach or take any conductive object closer to exposed energized parts than the employer's established minimum approach distance, unless the measures outlined in 1926.960(c)(1)(iii)(A) - (C) were met:  (a) On or about 08/22/2017 - 1022 County Road 768, Cullman, AL, the employer failed to ensure that no employee approached within 63 inches of an exposed power line energized at 7,200 volts without being protected with rubber insulating gloves and sleeves or insulating the power line/equipment using cover-ups, e.g. line hoses and/or blankets.