OAK CREEK, WI ·
OSHA Inspection: VINII, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of VINII, LLC in 6665 S. HOWELL AVE., OAK CREEK, WI 53154 (NAICS 238210). OSHA activity number 342583564.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VINII, LLC
- Site address
- 6665 S. HOWELL AVE.
- City
- OAK CREEK
- State
- WI
- ZIP
- 53154
- Mailing
- 7100 W FOND DU LAC AVE, MILWAUKEE, WI 53218
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 2
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.20 B02
- Issued
- Dec 22, 2017
- Abate by
- Jan 22, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): (a) The employer did not ensure that a safety program was maintained that called for frequent and regular inspections of the worksite that covered topics such as, but not limited to, fall protection, electrical hazards, struck-by hazards and caught-in-between hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.403 B01
- Issued
- Dec 22, 2017
- Abate by
- Dec 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: (a) The employer did not ensure that electrical equipment was safe from recognized hazards that could cause injury to employees. On or about August 22, 2017 an employee suffered electrical shock injuries when contact was made with a light fixture that was incorrectly installed. In the alternative... 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) The employer did not ensure that electrical equipment was installed according to listed and labeled procedures. On or about August 22, 2017 an employee suffered electrical shock injuries when contact was made with a light fixture that was incorrectly installed.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.417 B
- Issued
- Dec 22, 2017
- Abate by
- Dec 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.417(b): Equipment or circuits that were de-energized did not have tags attached at all points where such equipment or circuits could be energized: (a) The employer did not ensure that all sources of electrical energy were isolated when conducting work on electrical components that could become energized.
Recent events (2)
- · I (S) $0
- · Z (S) $0