Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: ANDIEMAC WATERPROOFING AND RESTORATION, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of ANDIEMAC WATERPROOFING AND RESTORATION, LLC in 33 N ST., NE, WASHINGTON, DC 20002 (NAICS 238190). OSHA activity number 342588423.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Andiemac Waterproofing and Restoration, LLC for free Get an email when a new federal OSHA severe-injury report for Andiemac Waterproofing and Restoration, LLC is published. One employer, no account, unsubscribe in one click.
Site address
33 N ST., NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
7084 PINDELL SCHOOL RD., FULTON, MD 20759
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 21, 2018
Abate by
Mar 8, 2018
Penalty
Initial $5,174 · Current $5,174
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:     a)  Tenth Floor, Multi-point suspension Scaffold - On or about August, 24, 2017, water proofers had to climb from the building's 10th floor up 44 inches onto the lower platform  since a safe means to access the scaffold's platform was not provided.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $5174
  • · Z (S) $5174

1926.451 F03

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2018
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:   a)  Tenth Floor, Column 61 - On or about August 24, 2017, workers were assigned to install waterproofing from a  scaffold before the scaffold was inspected by a competent person for visible defects, such as but not limited to, having no standard guardrails in all areas where a fall could occur or not providing workers with all necessary components of a personal fall arrest systems.   No abatement certification or documentation required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $12934

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2018
Abate by
Mar 1, 2018
Penalty
Initial $12,934 · Current $12,934
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a)  Tenth Floor, Column 61 - On or about August 24, 2017, construction workers applying waterproofing to the edge of a concrete floor slab were not provided with an independent lifeline with which to attach their personal fall arrest equipment or a guardrail system meeting the requirements of 1926.451(g)(4) and were exposed to an 80 foot fall from the outside perimeter edges of a mason's multi-point scaffold platform .  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $12934
  • · Z (S) $12934

1926.454 A

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 21, 2018
Abate by
Mar 13, 2018
Penalty
Initial $6,467 · Current $6,467
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:   Tenth Floor, Multi-point Suspension Scaffold - Workers installing bituminous waterproofing materials from the platform of a multi-point suspension scaffold did not receive training in the hazards particular to that type of scaffold, including, but not limited to, scaffold platforms, access and fall protection.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $6467
  • · Z (S) $6467