WALWORTH, NY ·
OSHA Inspection: 3655 HIGH STREET LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of 3655 HIGH STREET LLC in WALWORTH VILLAGE APARTMENTS ACADAMY STREET, WALWORTH, NY 14568 (NAICS 238990). OSHA activity number 342593787.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3655 HIGH STREET LLC
- Site address
- WALWORTH VILLAGE APARTMENTS ACADAMY STREET
- City
- WALWORTH
- State
- NY
- ZIP
- 14568
- Mailing
- 835 EAST MAIN STREET, ROCHESTER, NY 14605
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B01
- Issued
- Nov 13, 2017
- Abate by
- Dec 29, 2017
- Penalty
- Initial $2,716 · Current $2,037 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) At the jobsite, on or about 8/29/17: Workers were working near window openings on the second floor, at the Northwest end, without fall protection of any kind. The second floor deck was 10 feet 10 inches from ground and the sill was measured 2 feet from the second floor deck. b) At the jobsite, on or about 8/29/17: Workers were working near window openings on the second floor, at the Northeast end, without fall protection of any kind. The second floor deck was 10 feet 10 inches from ground and the sill was measured 2 feet from the second floor deck.
Recent events (2)
- · I (S) $2037
- · Z (S) $2716
1926.1052 B03
- Issued
- Nov 13, 2017
- Abate by
- Dec 29, 2017
- Penalty
- Initial $3,803 · Current $2,852 Reduced
General-duty citation text
29 CFR 1926.1052(b)(3): Treads for temporary stairway service were not installed the full width and/or depth of the stair: a) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where the treads were not installed the full depth of the stair. This stairway was in Building A, adjacent to the breezeway entrance. b) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where the treads were not installed the full depth of the stair. This stairway was in Building A, at the South entrance. c) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where the treads were not installed the full depth of the stair. This stairway was in Building B, at the West entrance.
Recent events (2)
- · I (S) $2852.25
- · Z (S) $3803
1926.1052 C01 I
- Issued
- Nov 13, 2017
- Abate by
- Dec 29, 2017
- Penalty
- Initial $3,803 · Current $2,852 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway in Building A at the breezeway entrance, where no handrail was provided on the first flight of stairs.
Recent events (2)
- · I (S) $2852.25
- · Z (S) $3803
1926.1052 C04
- Issued
- Nov 13, 2017
- Abate by
- Nov 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(4): Mid-rails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stair-rail system and the stairway steps: a) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no mid-rail was provided. This stairway was in Building A, adjacent to the breezeway entrance. b) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no mid-rail was provided. This stairway was in Building A, at the South entrance. c) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no mid-rail was provided. This stairway was in Building B, at the West entrance.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1052 C12
- Issued
- Nov 13, 2017
- Abate by
- Nov 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: a) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no guardrail system was provided at the first landing. This stairway was in Building A, adjacent to the breezeway entrance. b) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no guardrail system was provided at the first landing. This stairway was in Building A, at the South entrance. c) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no guardrail system was provided at the first landing. This stairway was in Building B, at the West entrance.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238990)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342593787.