MERTZTOWN, PA ·
OSHA Inspection: SOLT'S SAWMILL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOLT'S SAWMILL, INC. in 33 S PARK AVE., MERTZTOWN, PA 19539 (NAICS 321113). OSHA activity number 342594108.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOLT'S SAWMILL, INC.
- Site address
- 33 S PARK AVE.
- City
- MERTZTOWN
- State
- PA
- ZIP
- 19539
- Mailing
- 33 S PARK AVE., MERTZTOWN, PA 19539
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 19
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Sep 7, 2017
- Abate by
- Sep 26, 2017
- Penalty
- Initial $2,173 · Current $1,950 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. (a) Sawmill: On or about August 29, 2017, employee(s) were changing the teeth on the bottom blade of the Head Saw without the use of lockout device on the electrical energy source. No energy control program, employee training and periodic inspection was established for the maintenance and repair of the Head Saw system at this facility. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date, and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $1950
- · Z (S) $2173
1910.147 C04 I
- Issued
- Sep 7, 2017
- Abate by
- Sep 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. (a) Sawmill: On or about August 29, 2017, employee(s) were changing the teeth on the bottom blade of the Head Saw without the use of lockout device on the electrical energy source. Specific Lockout / Tagout procedures for shutting down, isolating, blocking and securing the Head Saw system at this facility were not developed. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date, and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 D04 I
- Issued
- Sep 7, 2017
- Abate by
- Sep 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Sawmill: On or about August 29, 2017, employee(s) were changing the teeth on the bottom blade of the Head Saw without the use of lockout device on the electrical energy source. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date, and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.334 A02 I
- Issued
- Sep 7, 2017
- Abate by
- Sep 26, 2017
- Penalty
- Initial $2,173 · Current $1,950 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord- and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence for possible internal damage (such as pinched or crushed outer jacket): (a) Sawmill: On or about August 29, 2017 the Stihl electric chain saw, model E14, was not visually inspected prior to use and had damage to the outer sheath jacket exposing the internal insulated conductors. (b) Sawmill: On or about August 29, 2017 the Stihl electric chain saw, model MSE 180C, was not visually inspected prior to use and had damage to the outer sheath jacket exposing the internal insulated conductors. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date, and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $1950
- · Z (S) $2173
More inspections in this industry (NAICS 321113)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342594108.