OLYPHANT, PA —
OSHA Inspection: REVOLUTIONARY HOME HEALTH, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of REVOLUTIONARY HOME HEALTH, INC. in 1619 MAIN STREET, OLYPHANT, PA 18447 (NAICS 621610). OSHA activity number 342598604.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REVOLUTIONARY HOME HEALTH, INC.
- Site address
- 1619 MAIN STREET
- City
- OLYPHANT
- State
- PA
- ZIP
- 18447
- Mailing
- 1619 MAIN STREET, OLYPHANT, PA 18447
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 621610
- Employees
- 25
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.36 G01
- Issued
- Sep 7, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $4,310 · Current $3,233 Reduced
General-duty citation text
29 CFR 1910.36(g)(1): The ceiling of an exit route was not at least seven feet six inches (2.3 m) high. a) Interior stairway from ground floor to basement, the height of the stairway, which served as the only interior egress to and from the basement, did not have minimum ceiling height of seven feet six inches, on or about August 30, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3232.5
- — Z (S) $4310
1910.28 B11 II
- Issued
- Sep 7, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails in accordance with Table D-2, Stairway Handrail Requirements. a) Interior stairway leading from ground floor to basement, no handrail was mounted on at least enclosed side, on the first flight of stairs, on or about, August 30, 2017. b) Interior stairway leading from ground floor to basement, no handrail was mounted on the wall on the bottom flight of stairs, on or about, August 30, 2017. c) Interior stairway on the east side leading from ground floor to second floor, no intermediate handrail was mounted on the top flight of stairs, on or about, August 30, 2017. d) Interior stairway on the west side leading from ground floor to second floor, no intermediate handrail was mounted on the top flight of stairs, on or about, August 30, 2017. e) Interior stairway leading from second floor to third floor, no intermediate handrail was mounted on the top flight of stairs, on or about, August 30, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.25 B05 I
- Issued
- Sep 7, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.25(b)(5) A door or a gate opened directly on a stairway, a platform was provided, and the swing of the door or gate reduced the platform's effective usable depth to less than 20 inches (51 cm) for platforms installed before January 17, 2017. a) Interior basement stairway leading to exterior exit, the exterior door opened inward directly on the stairway and the swing of the door reduced the effective usable depth of the winder, which served as platform, to only several inches, on or about, August 30, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 IX
- Issued
- Sep 7, 2017
- Abate by
- Oct 12, 2017
- Penalty
- Initial $3,232 · Current $2,424 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard: a) Interior stairway leading from ground floor to basement, an incandescent light fixture and its bulb were not guarded against breakage and contact, on or about, August 30, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2424
- — Z (S) $3232
More inspections in this industry (NAICS 621610)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342598604.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.