NEWFANE, NY —
OSHA Inspection: CHARLES J. MARTIN INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHARLES J. MARTIN INC. in 2974 LOCKPORT-OLCOTT ROAD, NEWFANE, NY 14108 (NAICS 238160). OSHA activity number 342600855.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHARLES J. MARTIN INC.
- Site address
- 2974 LOCKPORT-OLCOTT ROAD
- City
- NEWFANE
- State
- NY
- ZIP
- 14108
- Mailing
- 3055 MAPLE ROAD, NEWFANE, NY 14108
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 G01 I
- Issued
- Sep 21, 2017
- Penalty
- Initial $2,897 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 08/28/17, on jobsite at a house at 2974 Lockport Olcott Rd., Newfane , NY: Employees were exposed to a potential fall of approx. 17 ft. from the pik on a Ladder Jack Scaffold erected on the right side of the house while standing on the pik engaged in roof tear-off work. No Fall protection system was being utilized. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2897
1926.501 B11
- Issued
- Sep 21, 2017
- Penalty
- Initial $3,622 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 08/28/17, on the upper roof of a house at 2974 Lockport Olcott Rd., Newfane, NY: Five employees engaged in roofing tear-off work on a steep roof on the right side of the house were exposed to a fall of approx. 20 foot. No fall protection system was being utilized. Pitch of the roof was approx. 8 in 12. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2450
- — Z (S) $3622
1926.501 B10
- Issued
- Sep 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system alone: a) On or about 08/28/17, on the low slope porch roof of a house at 2974 Lockport Olcott Rd., Newfane , NY: Two employees engaged in roofing work were exposed to a fall of approx. 12 ft. No fall protection system was utilized on this roof. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Sep 21, 2017
- Penalty
- Initial $2,173 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) On or about 08/28/17, on the front side of a house at 2974 Lockport Olcott Rd., Newfane , NY: Employees used an extension ladder to access the porch roof from the ground. The side rails of that ladder only extended approx. 12 inches above the roof. b) On or about 08/28/17, on the front side of a house at 2974 Lockport Olcott Rd., Newfane , NY: An employee used the support ladder of a Ladder Jack Scaffold erected on the porch roof to exit the upper roof onto the scaffold pik. The side rails of that support ladder only reached to the bottom of the gutter which was below the roof edge. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2173
More inspections at Charles J. Martin INC.
View Charles J. Martin INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342600855.