Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADA ENERGY SERVICE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADA ENERGY SERVICE, LLC in E GWERTHNEY 1-5, EARLSBORO, OK 74840 (NAICS 213111). OSHA activity number 342605250.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ADA Energy Service, LLC — free Get an email when a new federal OSHA severe-injury report for ADA Energy Service, LLC is published. One employer, no account, unsubscribe in one click.
Site address
E GWERTHNEY 1-5
City
EARLSBORO
State
OK
ZIP
74840
Mailing
13710 COUNTY RD 1550, ADA, OK 74820
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
22
Ownership type
A

5 citations on file for this inspection.

1910.22 C

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2018
Abate by
Jan 12, 2018
Penalty
Initial $3,622 · Current $2,173 Reduced
29 CFR 1910.22(c): The employer did not provide, and ensure each employee used, a safe means of access and egress to and from walking-working surfaces:  Derrickman Platform. On or about August 31, 2017 and at times prior thereto, an employee working from the derrickman's platform was not provided with a safe auxiliary means of egress (Geronimo Line). Employees were exposed to a fall hazard of more than 4 feet in the event of a fire or explosion.
Recent events (2)
  • — I (S) $2173.2
  • — Z (S) $3622

1910.28 B01 I

Serious Gravity 5 1 instance 8 exposed
Issued
Jan 4, 2018
Abate by
Jan 12, 2018
Penalty
Initial $3,622 · Current $2,173 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  V-Door area. On or about August 31, 2017 and at times prior thereto, standard guardrail systems or other fall protection systems were not present near the V-Door area. Employees were exposed to a fall from elevation of more than 4 feet while performing routine work.
Recent events (2)
  • — I (S) $2173.2
  • — Z (S) $3622

1910.28 B03 II

Serious Gravity 5 1 instance 22 exposed
Issued
Jan 4, 2018
Abate by
Jan 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(3)(ii): The employer did not ensure each employee is protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems:   Drilling Rig Floor. On or about August 31, 2017 and at times prior thereto, employees were exposed to trip and fall hazards form an un-protected  hole  approximately 44 inches wide and 72 inches long and 6 inches deep on the drilling rig floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 A

Serious Gravity 5 3 instances 22 exposed
Issued
Jan 4, 2018
Abate by
Jan 29, 2018
Penalty
Initial $3,622 · Current $2,173 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  On or about August 31, 2017, and at times prior thereto,  the employer did not ensure employees were provided with flame resistant clothing (FRC) when working in areas where there was a potential for hydrocarbons to be present, exposing the employees to fire and explosion hazards.
Recent events (2)
  • — I (S) $2173.2
  • — Z (S) $3622

1910.151 C

Serious Gravity 5 1 instance 22 exposed
Issued
Jan 4, 2018
Abate by
Jan 29, 2018
Penalty
Initial $3,622 · Current $2,173 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use  Mud mixing area. On or about August 31, 2017 and at times prior thereto, employees were exposed to corrosive materials including, but not limited to, caustic soda beads and soda ash, and were not provided with emergency eyewash and shower facilities for immediate use within the work area. Employee(s) were exposed to potential chemical burns on the skin and eyes.
Recent events (2)
  • — I (S) $2173.2
  • — Z (S) $3622

View ADA Energy Service, LLC's full OSHA safety record →