FORT LEE, NJ —
OSHA Inspection: NEW YORK CHRISTMAS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NEW YORK CHRISTMAS in MAIN STREET, FORT LEE, NJ 07024 (NAICS 561920). OSHA activity number 342609344.
Where did this inspection happen?
- Establishment
- NEW YORK CHRISTMAS
- Site address
- MAIN STREET
- City
- FORT LEE
- State
- NJ
- ZIP
- 07024
- Mailing
- 400 BARRETTO STREET, BRONX, NY 10451
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561920
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $4183.00 · Current $2928.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A) Exterior, In bucket truck: An employee was exposed to head injuries while working in an area with overhead hazards. The employee was not protected by a hard hat or protective helmet, on or about July 26th, 2017.
Recent events (2)
- — I (S) $2928.1
- — Z (S) $4183
1926.451 F06
- Issued
- Penalty
- Initial $4183.00 · Current $2928.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows: *Insulated Lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 300 volts. 3 feet (0.9 m) 300 volts to 50 kv. 10 feet (3.1 m) More than 50 kv..... 10 feet (3.1 m) plus 2 times the length 0.4 inches (1.0 cm) of the line for each 1 kv over insulator, but never 50 kv. less than 10 feet (3.1 m). ____________________ ________________________ _______________________ *Uninsulated lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 50 kv..... 10 feet (3.1 m). More than 50 kv..... 10 feet (3.1 m) plus 2 times the length of 0.4 inches (1.0 cm) the line insulator, for each 1 kv over but never less than 50 kv. 10 feet (3.1 m). ____________________ ________________________ _______________________ Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines. A) Exterior, In lift: Employees were exposed to electrocution hazards while working in an aerial lift approximately 1 foot away from energized, un-insulated primary power lines, on or about July 26th, 2017.
Recent events (2)
- — I (S) $2928.1
- — Z (S) $4183
More inspections in this industry (NAICS 561920)
SAN DIEGO, CA—2026-06-05
SAN DIEGO COMIC CONVENTION
LOUISVILLE, KY—2026-03-18
68963 - FREEMAN EXPOSITIONS LLC
WEST WARWICK, RI—2026-02-11
RYAN DESIGNS, LLC
WEST WARWICK, RI—2026-02-10
RYAN DESIGNS, LLC
ALTAMONTE SPRINGS, FL—2026-01-14
PINAPS LLC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342609344.