YIGO, GU —
OSHA Inspection: WOLF CREEK FEDERAL SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WOLF CREEK FEDERAL SERVICES, INC. in BUILDING 25024 ANDERSEN AFB, YIGO, GU 96929 (NAICS 236220). OSHA activity number 342610581.
Where did this inspection happen?
- Establishment
- WOLF CREEK FEDERAL SERVICES, INC.
- Site address
- BUILDING 25024 ANDERSEN AFB
- City
- YIGO
- State
- GU
- ZIP
- 96929
- Mailing
- 773 WEST MARINE CORPS DR., HAGATNA, GU 96910
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.502 D06 I
- Issued
- Penalty
- Initial $1884.00 · Current $1319.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(6)(i): Snap hooks were connected directly to webbing, rope or wire rope: Building 25024, Andersen AFB: Employees on the roof installing guardrail components had their lanyard anchorage snaphooks wrapped around a pipe mounting bracket and attached to the lanyard webbing itself. Employee(s) were exposed to fall hazards of up to 108 inches.
Recent events (2)
- — I (O) $1318.8
- — Z (S) $1884
1926.502 D15
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee: Building 25024, Andersen AFB: The pipe mounting bracket used to anchor the lanyards was not evaluated to determine if it supported at least 5,000 pounds per employee or maintained a safety factor of at least two. Employees were exposed to fall hazards of up to 108 inches.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.502 D17
- Issued
- Penalty
- Initial $1884.00 · Current $1319.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: Building 25024, Andersen AFB: A worker on the roof installing guardrail components had his lanyard snaphook attached to the positioning device side dee-ring at waist level. The employee was exposed to fall hazards of up to 108 inches.
Recent events (2)
- — I (O) $1318.8
- — Z (S) $1884
More inspections at WOLF CREEK FEDERAL SERVICES, INC.
HUNTSVILLE, AL—2020-09-10 00:00:00
WOLF CREEK FEDERAL SERVICES, INC.
YIGO, GU—2017-11-28 00:00:00
WOLF CREEK FEDERAL SERVICES, INC.
SAIPAN, MP—2017-07-02 00:00:00
WOLF CREEK FEDERAL SERVICES, INC.
HAGATNA, GU—2016-11-02 00:00:00
WOLF CREEK FEDERAL SERVICES, INC.
View WOLF CREEK FEDERAL SERVICES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
ROCHESTER, NH—2026-07-17 00:00:00
STAR CONSTRUCTION SVS INC
WHITESTOWN, IN—2026-07-17 00:00:00
CENTRAL WELDING INC
MOUNTAIN LAKES, NJ—2026-07-17 00:00:00
JOHN CARUSO BUILDERS LLC
FAIRFAX, VA—2026-07-17 00:00:00
RYCON CONSTRUCTION, INC.
SHAWNEE, KS—2026-07-16 00:00:00
BRATTON BROTHERS CONTRACTING INC
More inspections in GU
BARRIGADA, GU—2026-01-22 00:00:00
DURI CORPORATION
TAMUNING, GU—2026-01-21 00:00:00
DLR CORPORATION
BARRIGADA, GU—2026-01-21 00:00:00
DURI CORPORATION
TAMUNING, GU—2026-01-20 00:00:00
MG CONSTRUCTION COMPANY
BARRIGADA, GU—2026-01-20 00:00:00
PFM -VERTEX-LMS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342610581.