Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FIBERTEC, INC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of FIBERTEC, INC in 35 SCOTTLAND BOULEVARD, BRIDGEWATER, MA 02324 (NAICS 326199). OSHA activity number 342610979.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fibertec, INC — free Get an email when a new federal OSHA severe-injury report for Fibertec, INC is published. One employer, no account, unsubscribe in one click.
Establishment
FIBERTEC, INC
Site address
35 SCOTTLAND BOULEVARD
City
BRIDGEWATER
State
MA
ZIP
02324
Mailing
35 SCOTTLAND BOULEVARD, BRIDGEWATER, MA 02324
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
38
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 5 7 instances 38 exposed
Issued
Jan 10, 2018
Abate by
Mar 2, 2018
Penalty
Initial $6,467 · Current $6,467
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a potential catastrophic fire and/or explosion of a gas-fired batch oven.  1) On or about August 18th, 2017 and at times prior, the employer did not ensure that employees were protected from being hit by the explosion-relief vents, when activated.  2) On or about August 18th, 2017, and at times prior, the employer did not establish regularly scheduled inspections, testing, and maintenance of all oven safety devices.  3) On or about August 18th, 2017, and at times prior, the employer did not ensure that the ovens had more than one gas safety shut off valve, and that they were piped in series.  4) On or about August 18th, 2017, and at times prior, the employer did not develop and implement a schedule for making tightness checks on all gas safety shutoff valves.
Recent events (1)
  • — Z (S) $6467

View Fibertec, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342610979.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.