Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: PROGRESS GROUP INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of PROGRESS GROUP INC. in 5001 38TH STREET ROAD NW, WASHINGTON, DC 20016 (NAICS 238170). OSHA activity number 342612207.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Progress Group INC. for free Get an email when a new federal OSHA severe-injury report for Progress Group INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PROGRESS GROUP INC.
Site address
5001 38TH STREET ROAD NW
City
WASHINGTON
State
DC
ZIP
20016
Mailing
4310 ASPEN HILL ROAD, ROCKVILLE, MD 20853
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 29, 2017
Abate by
Oct 10, 2017
Penalty
Initial $3,803 · Current $2,400 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):      a) On or about August 10, 2017; Roof area residential construction; employees were observed working on the roof area of the residential home without fall protection in place to protect them from falling an estimated 25-27 feet to ground level while installing siding on the dormers.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.