PLOVER, WI —
OSHA Inspection: MONOGRAM APPETIZERS, LLC
Federal Agency inspection · Health discipline
At a glance
On , OSHA opened a federal Agency health inspection of MONOGRAM APPETIZERS, LLC in 300 MOORE ROAD, PLOVER, WI 54467 (NAICS 311412). OSHA activity number 342616414.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MONOGRAM APPETIZERS, LLC
- Site address
- 300 MOORE ROAD
- City
- PLOVER
- State
- WI
- ZIP
- 54467
- Mailing
- 300 MOORE ROAD, PLOVER, WI 54467
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311412
- Employees
- 350
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.1000 A02
- Issued
- Dec 19, 2017
- Penalty
- Initial $12,675 · Current $7,605 Reduced
C730
General-duty citation text
29 CFR 1910.1000(a)(2): Other substances -- 8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a "C", shall not exceed the 8-hour Time Weighted Average given for that substance any 8-hour work shift of a 40-hour work week. a) On 9/5/17, a Line M2 Machine Operator was exposed to 397% of the 8 hour Time Weighted Average Carbon Monoxide exposure limit. The 8-hour Time Weighted Average exposure limit for Carbon Monoxide is 50 ppm. The Line M2 Machine Operator was exposed to a Carbon Monoxide 8-hour Time Weighted Average of 198.6 ppm over a 445 minute time period. b) On 9/5/17, a Line M3 Product Inspector was exposed to 316% of the 8 hour Time Weighted Average Carbon Monoxide exposure limit. The 8-hour Time Weighted Average exposure limit for Carbon Monoxide is 50 ppm. The Line M3 Product Inspector was exposed to a Carbon Monoxide 8-hour Time Weighted Average of 157.8 ppm over a 415 minute time period. c) On 9/5/17, a Line M3 VCS Operator was exposed to 293% of the 8 hour Time Weighted Average Carbon Monoxide exposure limit. The 8-hour Time Weighted Average exposure limit for Carbon Monoxide is 50 ppm. The Line M3 VCS Operator was exposed to a Carbon Monoxide 8-hour Time Weighted Average of 146.6 ppm over a 445 minute time period. d) On 9/5/17, a Line M3 Case Sealer was exposed to 260% of the 8 hour Time Weighted Average Carbon Monoxide exposure limit. The 8-hour Time Weighted Average exposure limit for Carbon Monoxide is 50 ppm. The Line M3 Case Sealer was exposed to a Carbon Monoxide 8-hour Time Weighted Average of 129.8 ppm over a 445 minute time period.
Recent events (2)
- — I (S) $7605
- — Z (S) $12675
1910.1000 E
- Issued
- Dec 19, 2017
- Abate by
- Jan 19, 2018
- Penalty
- Initial $0 · Current $0
C730
General-duty citation text
29 CFR 1910.1000(e): To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134. a) On or about 9/5/17, the M3 Fryer Burner Section ventilation system was not rebalanced to provide the additional fresh air needed and/or control the additional carbon monoxide generated when 40 of the 100 burner units were replaced on the M3 Line natural gas fueled Fryer Unit during the previous 3 day weekend. b) On or about 9/5/17, Supervisors did not remove employees as an administrative control, from the M2 and M3 Production Lines Area when employees were experiencing severe headaches, nausea and other symptoms.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Dec 19, 2017
- Abate by
- Jan 19, 2018
- Penalty
- Initial $12,675 · Current $7,605 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets. a) On or about 9/5/17, the employer's hazard communication training did not include the potential of carbon monoxide exposure from the natural gas fueled equipment. b) On or about 9/5/17, the employer's hazard communication training did not include training natural gas fuel equipment operators to report abnormal burning conditions, such as flame color or flame height, to supervisors and/or maintenance for repairs.
Recent events (2)
- — I (S) $7605
- — Z (S) $12675
More inspections at Monogram Appetizers, LLC
View Monogram Appetizers, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311412)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342616414.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.