OSHA Inspection: SMITH BROS. MEATS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SMITH BROS. MEATS, INC. in 822 SOUTH DIVISION ST, COLBY, WI 54421 (NAICS 424470). OSHA activity number 342620465.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Smith Bros. Meats, INC. for free Get an email when a new federal OSHA severe-injury report for Smith Bros. Meats, INC. is published. One employer, no account, unsubscribe in one click.
Site address
822 SOUTH DIVISION ST
City
COLBY
State
WI
ZIP
54421
Mailing
822 SOUTH DIVISION ST, COLBY, WI 54421
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424470
Employees
13
Ownership type
Private (A)

2 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 2, 2017
Abate by
Oct 17, 2017
Penalty
Initial $2,897 · Current $2,030 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Above sausage stuffer; An extension cord with an electrical outlet box not designed for wet areas was being used near water.
Recent events (2)
  • · I (S) $2030
  • · Z (S) $2897

1910.305 J02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 2, 2017
Abate by
Oct 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:  (a) Above sausage stuffer; A receptacle that was not a ground fault circuit interrupter (GFCI) was installed in a wet location.