Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WATER TIGHT ROOFING CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WATER TIGHT ROOFING CORP. in 84-54 248TH ST, BELLEROSE, NY 11426 (NAICS 238160). OSHA activity number 342622941.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Water Tight Roofing Corp. — free Get an email when a new federal OSHA severe-injury report for Water Tight Roofing Corp. is published. One employer, no account, unsubscribe in one click.
Site address
84-54 248TH ST
City
BELLEROSE
State
NY
ZIP
11426
Mailing
118 PARIS COURT, WEST ISLIP, NY 11795
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 5, 2018
Penalty
Initial $1,663 · Current $1,663
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  A.) On or about September 8, 2017 at 84-58 248th Street, Bellerose, NY 11426  Employees were observed working without hard hats exposed to struck-by hazards.  ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (1)
  • — Z (S) $1663

1926.102 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  A.) On or about September 8, 2017 at 84-58 248th Street, Bellerose, NY 11426  Employees were observed using a nail gun while securing roofing material to a commercial rooftop without eye protection exposing employees to flying particle hazards.  ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (1)
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 2 instances 4 exposed
Issued
Mar 5, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  A.) On or about September 8, 2017 at 84-58 248th Street, Bellerose, NY 11426  Employees were observed installing roof shingles on a commercial rooftop approximately twenty (20) feet above the lower level without fall protection.  B.) On or about September 8, 2017 at 84-58 248th Street, Bellerose, NY 11426  An employee was observed standing on a ladder jack scaffold installing roof shingles to a commercial rooftop approximately eighteen (18) feet above the lower level without fall protection.  ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (1)
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 5, 2018
Penalty
Initial $1,663 · Current $1,663
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.  A.) On or about September 8, 2017 at 84-58 248th Street, Bellerose, NY 11426  A portable ladder used by employees to access a commerical rooftop was not extended at least three (3) feet above the upper landing surface exposing employees to fall hazards.  ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (1)
  • — Z (S) $1663

View Water Tight Roofing Corp.'s full OSHA safety record →