Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARIZON BUILDING SYSTEMS LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ARIZON BUILDING SYSTEMS LLC in 9231 GALENA RD., YORKVILLE, IL 60560 (NAICS 238120). OSHA activity number 342623113.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arizon Building Systems LLC — free Get an email when a new federal OSHA severe-injury report for Arizon Building Systems LLC is published. One employer, no account, unsubscribe in one click.
Site address
9231 GALENA RD.
City
YORKVILLE
State
IL
ZIP
60560
Mailing
11880 DORSETT RD., SAINT LOUIS, MO 63143
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
2
Ownership type
A

1 citation on file for this inspection.

1926.752 A01

Other-than-serious 1 instance 2 exposed
Issued
Nov 1, 2017
Abate by
Nov 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.752(a)(1): Before authorizing the commencement of steel erection, the controlling contractor shall ensure that the steel erector is provided with written notification that the concrete in the footings, piers and walls and the mortar in the masonry piers and walls has attained, on the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during steel erection.  On or about September 7, 2017, the controlling contractor failed to provide the steel erector with written notice, as required by this standard, before commencement of steel erection.  Abatement certification is required of this item in accordance with requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (O) $0

View Arizon Building Systems LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342623113.