PITTSTON, PA —
OSHA Inspection: ACTION LIFT INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ACTION LIFT INC. in 1 MEMCO DR., PITTSTON, PA 18640 (NAICS 811310). OSHA activity number 342632197.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACTION LIFT INC.
- Site address
- 1 MEMCO DR.
- City
- PITTSTON
- State
- PA
- ZIP
- 18640
- Mailing
- 1 MEMCO DR., PITTSTON, PA 18640
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 7, 2017
- Abate by
- Dec 27, 2017
- Penalty
- Initial $5,387 · Current $4,040 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Service Shop: Procedures were not utilized for the control of potentially hazardous energy while employees were performing service of a powered industrial truck (Unicarrier Model MCU1F2A30LV/SN CU1F2-9Q20723), exposing employees to an amputation hazard, on or about September 11, 2017. Abatement Certification Required.
Recent events (2)
- — I (S) $4040.25
- — Z (S) $5387
1910.147 C06 I
- Issued
- Nov 7, 2017
- Abate by
- Dec 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Service Shop: The employer did not conduct a periodic inspection of the energy control procedures including, but not limited to, powered industrial trucks at least annually, on or about September 13, 2017. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Action Lift INC.
View Action Lift INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811310)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342632197.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.