Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIVINT SOLAR, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VIVINT SOLAR, INC in 4448 AUBREY AVE, PHILADELPHIA, PA 19114 (NAICS 238210). OSHA activity number 342632262.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vivint Solar, INC — free Get an email when a new federal OSHA severe-injury report for Vivint Solar, INC is published. One employer, no account, unsubscribe in one click.
Establishment
VIVINT SOLAR, INC
Site address
4448 AUBREY AVE
City
PHILADELPHIA
State
PA
ZIP
19114
Mailing
1800 WEST ASHTON BOULEVARD, LEHI, UT 84043
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
4260
Ownership type
A

4 citations on file for this inspection.

1926.1053 B22

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 17, 2017
Abate by
Nov 30, 2017
Penalty
Initial $9,959 · Current $9,959
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall:  a) 4448 Aubrey Ave, Philadelphia, PA - On or about 5/17/17, employees were carrying solar panels up a l32 ft ladder and onto the roof, exposing the employees to fall hazards.
Recent events (3)
  • — F (S) $9959
  • — C (S) $9959
  • — Z (S) $9959

1926.1053 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 17, 2017
Abate by
Nov 24, 2017
Penalty
Initial $126,749 · Current $58,395 Reduced
29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    (a) 4448 Aubrey Ave, Philadelphia - On or about 5/17/17, employees accessing a residential roof climbed a 32ft extension ladder that did not extend at least 3 ft. above the roof landing, exposing employees to fall hazards.  Vivint Solar, Inc. (dba Vivint Solar Developer, LLC) was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 898846, citation number 1, item number 2, and was affirmed as a final order on 6/10/2013, with respect to a workplace located at 16 Chapin Rd, Pine Brook, NJ  07058.  Vivint Solar, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 758441, citation number 1, item number 2, and was affirmed as a final order on 4/8/2013, with respect to a workplace located at1 Doric Ave, Parsippany, NJ  07054
Recent events (3)
  • — F (S) $58395
  • — C (R) $126749
  • — Z (R) $126749

1926.1053 B05 I

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 17, 2017
Abate by
Nov 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).  (a) 4448 Aubrey Ave, Philadelphia - On or about 5/17/17, employees using a 32ft extension ladder was not used at an angle of approximately one-quarter of it's height, exposing employees to fall hazards.  Vivint Solar Developer, LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 988131, citation number 1, item number 1, and was affirmed as a final order on 11/4/14, with respect to a workplace located at 79 Cheever Ave, Dracut, MA.
Recent events (3)
  • — F (S) $0
  • — C (R) $0
  • — Z (R) $0

1926.503 B01

Other-than-serious 1 instance 1 exposed
Issued
Nov 17, 2017
Abate by
Dec 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a)  4448 Aubrey Ave - On or about 5/17/17, the employer did not maintain written certification records that included the signature of the person conducting the training or the signature of the employee.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Vivint Solar, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342632262.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.