Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DYNAMIC CONSTRUCTION SERVICES INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DYNAMIC CONSTRUCTION SERVICES INC in NAVAL BASE POINT LOMA FUEL LINEPIER AREA, SAN DIEGO, CA 92111 (NAICS 237120). OSHA activity number 342633492.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dynamic Construction Services INC — free Get an email when a new federal OSHA severe-injury report for Dynamic Construction Services INC is published. One employer, no account, unsubscribe in one click.
Site address
NAVAL BASE POINT LOMA FUEL LINEPIER AREA
City
SAN DIEGO
State
CA
ZIP
92111
Mailing
3020 OLD RANCH PARKWAY, 3RD FLOOR, SEAL BEACH, CA 90740
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
20
Ownership type
A

1 citation on file for this inspection.

1926.1053 A01 II

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Oct 23, 2017
Penalty
Initial $1,847 · Current $0 Reduced
29 CFR 1926.1053(a)(1)(ii): Each portable ladder that is not self-supporting: At least four times the maximum intended load, except that each extra-heavy-duty type 1A metal or plastic ladders shall sustain at least 3.3 times the maximum intended load. The ability of a ladder to sustain the loads indicated in this paragraph shall be determined by applying or transmitting the requisite load to the ladder in a downward vertical direction when the ladder is placed at an angle of 75 1/2 degrees from the horizontal. Ladders built and tested in conformance with the applicable provisions of appendix A will be deemed to meet this requirement.  Worksite Near Fuel Pier: A blue Werner extension ladder was not erected as close to a pitch of 75 1/2 degrees from the horizontal plane for optimum resistance to protect against the bottom of the ladder sliding out.  The ladder needs to be set up at the proper angle from the wall or upper support equal to one-quarter of the length of the ladder side rails.
Recent events (3)
  • — R (S) $0
  • — C (S) $1847
  • — Z (S) $1847

View Dynamic Construction Services INC's full OSHA safety record →