Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: S&B PHARMA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of S&B PHARMA, INC. in 1733 GILSINN LANE, FENTON, MO 63026 (NAICS 325412). OSHA activity number 342633757.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S&B Pharma, INC. — free Get an email when a new federal OSHA severe-injury report for S&B Pharma, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
S&B PHARMA, INC.
Site address
1733 GILSINN LANE
City
FENTON
State
MO
ZIP
63026
Mailing
1733 GILSINN LANE, FENTON, MO 63026
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
90
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II B

Other-than-serious 1 instance 11 exposed
Issued
Jan 2, 2018
Abate by
Jan 29, 2018
Penalty
Initial $5,387 · Current $2,694 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:          The employer did not provide to the employee(s) energy control procedures which outlined the step for shutting down, isolating, and securing the Promatic Bipak Cartoner (Serial No. 7303232; Year of Construction: 2004; V 230, Hz 60, kW 9; Phase 3/T) to control hazardous energy.
Recent events (2)
  • — I (O) $2693.5
  • — Z (S) $5387

1910.147 C06 I

Other-than-serious 1 instance 11 exposed
Issued
Jan 2, 2018
Abate by
Jan 29, 2018
Penalty
Initial $5,387 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.      On or about September 06, 2017, at the jobsite located 1733 Gilsinn Lane, Fenton, Missouri, the employer did not conduct periodic inspections of the energy control procedures at least annually to ensure the procedures and requirements of the standard are being followed.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5387

1910.212 A03 II

Serious Gravity 5 1 instance 11 exposed
Issued
Jan 2, 2018
Penalty
Initial $5,387 · Current $5,387
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):       On or about September 06, 2017, at the jobsite located 1733 Gilsinn Lane, Fenton, Missouri, the employer did not ensure the point of operation for the Promatic Bipak Cartoner (Serial No. 7303232; Year of Construction: 2004; V 230, Hz 60, kW 9; Phase 3/T) was not guarded to prevent employee(s) from placing any part of their body in the danger zone during machine operations.
Recent events (2)
  • — I (S) $5387
  • — Z (S) $5387

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342633757.