FENTON, MO —
OSHA Inspection: S&B PHARMA, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of S&B PHARMA, INC. in 1733 GILSINN LANE, FENTON, MO 63026 (NAICS 325412). OSHA activity number 342633757.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S&B PHARMA, INC.
- Site address
- 1733 GILSINN LANE
- City
- FENTON
- State
- MO
- ZIP
- 63026
- Mailing
- 1733 GILSINN LANE, FENTON, MO 63026
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- Employees
- 90
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Jan 2, 2018
- Abate by
- Jan 29, 2018
- Penalty
- Initial $5,387 · Current $2,694 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: The employer did not provide to the employee(s) energy control procedures which outlined the step for shutting down, isolating, and securing the Promatic Bipak Cartoner (Serial No. 7303232; Year of Construction: 2004; V 230, Hz 60, kW 9; Phase 3/T) to control hazardous energy.
Recent events (2)
- — I (O) $2693.5
- — Z (S) $5387
1910.147 C06 I
- Issued
- Jan 2, 2018
- Abate by
- Jan 29, 2018
- Penalty
- Initial $5,387 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about September 06, 2017, at the jobsite located 1733 Gilsinn Lane, Fenton, Missouri, the employer did not conduct periodic inspections of the energy control procedures at least annually to ensure the procedures and requirements of the standard are being followed.
Recent events (2)
- — I (O) $0
- — Z (S) $5387
1910.212 A03 II
- Issued
- Jan 2, 2018
- Penalty
- Initial $5,387 · Current $5,387
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about September 06, 2017, at the jobsite located 1733 Gilsinn Lane, Fenton, Missouri, the employer did not ensure the point of operation for the Promatic Bipak Cartoner (Serial No. 7303232; Year of Construction: 2004; V 230, Hz 60, kW 9; Phase 3/T) was not guarded to prevent employee(s) from placing any part of their body in the danger zone during machine operations.
Recent events (2)
- — I (S) $5387
- — Z (S) $5387
More inspections in this industry (NAICS 325412)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342633757.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.