HACKENSACK, NJ —
OSHA Inspection: HOLLISTER CONSTRUCTION SERVICES, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HOLLISTER CONSTRUCTION SERVICES, LLC in 210 MAIN STREET, HACKENSACK, NJ 07601 (NAICS 236220). OSHA activity number 342639432.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOLLISTER CONSTRUCTION SERVICES, LLC
- Site address
- 210 MAIN STREET
- City
- HACKENSACK
- State
- NJ
- ZIP
- 07601
- Mailing
- 339 JEFFERSON ROAD, PARSIPPANY, NJ 07054
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 30
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 C02 II
- Issued
- Feb 5, 2018
- Penalty
- Initial $6,984 · Current $4,190 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: (a). Exterior 214 Main Street South-East Corner- Unstable objects were used to support a platform used by employees to access the building. Employees were accessing a building by walking up planking that was supported by a platform composed of hollow concrete blocks and wooden pallets, on or about September 13, 2017. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $4190.4
- — Z (S) $6984
1926.501 B04 I
- Issued
- Feb 5, 2018
- Abate by
- Mar 30, 2018
- Penalty
- Initial $8,148 · Current $4,889 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. (a). Interior 210 Main Street West Side- Employees on the first floor walking/working surface were not protected from falling through a hole leading to the basement by the use of personal fall arrest systems, covers, or guardrail systems erected around the hole. Employees working in the area were using the adjacent stairway to access the upper levels where additional work was being performed, on or about September 13, 2017. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $4888.8
- — Z (S) $8148
1926.1052 C12
- Issued
- Feb 5, 2018
- Abate by
- Mar 30, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926 (a). Interior 210 Main Street West Side- Employees on the first floor walking/working surface were not protected from falling into the stairway leading to the basement by the use of guardrail systems. Employees working in the area were using the adjacent stairway to access the upper levels where additional work was being performed, on or about September 13, 2017. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1052 C01
- Issued
- Feb 5, 2018
- Abate by
- Mar 30, 2018
- Penalty
- Initial $5,821 · Current $3,493 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: (a). Interior 214 Main Street East Entrance- A stairway with approximately five risers was not equipped with a handrail and was not equipped with a stair-rail system on each unprotected edge, on or about September 13, 2017. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $3492.6
- — Z (S) $5821
More inspections at Hollister Construction Services, LLC