EAST BOSTON, MA —
OSHA Inspection: TRANSPORTATION SECURITY ADMINISTRATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRANSPORTATION SECURITY ADMINISTRATION in BOSTON LOGAN INTERNATIONAL AIRPORT, EAST BOSTON, MA 02128 (NAICS 926120). OSHA activity number 342641198.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRANSPORTATION SECURITY ADMINISTRATION
- Site address
- BOSTON LOGAN INTERNATIONAL AIRPORT
- City
- EAST BOSTON
- State
- MA
- ZIP
- 02128
- Mailing
- 2 SERVICE ROAD, THIRD FLOOR, EAST BOSTON, MA 02128
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 926120
- Employees
- 1085
- Ownership type
- D
Citations
11 citations on file for this inspection.
1910.23 D13 I
- Issued
- Feb 26, 2018
- Abate by
- Jul 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(13)(i): A fixed ladder(s) did not have a clear width of at least 15 inches (38 cm) on each side of the ladder centerline to the nearest permanent object. Boston Logan International Airport: Employees were exposed to slip and fall hazards due to inadequate clearance from the side rails to the nearest permanent object: a. Delta Baggage Conveyor Room (Terminal A) - the distance between the side rail of a fixed ladder used to access the catwalks where the L3 X-ray machines were located and a guard for a conveyor belt ramp equipment was approximately 1/2 inch.
Recent events (1)
- — Z (S) $0
1910.28 B01 I
- Issued
- Feb 26, 2018
- Abate by
- Jul 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system: Boston Logan International Airport, Terminal A Baggage Conveyor Room: Employees were exposed to fall hazards on an open sided catwalk greater than eight (8) feet above a lower level and where a baggage conveyor was located.
Recent events (1)
- — Z (S) $0
1910.37 B05
- Issued
- Feb 26, 2018
- Abate by
- Jul 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): Boston Logan International Airport: A door was not identified to indicate its character: a. The door between Baggage Conveyor Room and B-5 Baggage Search (Inspection) Room (Terminal B) from the Conveyor Room side was not equipped with a sign to indicate that it was not designated as an exit.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- Feb 26, 2018
- Abate by
- Jul 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Boston Logan International Airport: Break Area adjacent to Security Check Point B-206 (Terminal B), a knockout of a duplex receptacle that energized a refrigerator and two (2) phones was missing exposing employees to electrical shock and arc flash hazards.
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Feb 26, 2018
- Abate by
- May 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Boston Logan International Airport: Terminal A Security Checkpoint - strain relief was not provided for a temporary power tap that energized an explosives detection equipment. The Transportation Security Administration was previously cited for an unsafe/unhealthful working condition of this occupational safety and health standard or its equivalent standard (name previously cited standard), which was contained in OSHA inspection number #885583, notice number 2, item number 6c and was affirmed as a final order on September 3, 2013, with respect to a workplace located at Logan International Airport, Boston, MA.
Recent events (1)
- — Z (S) $0
1910.305 J01 I
- Issued
- Feb 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact: Boston Logan International Airport: A temporary power tap used to energize a floor fan at Security Checkpoint (Terminal A) was damaged exposing employees to electrical shocks.
Recent events (1)
- — Z (S) $0
1910.23 D02
- Issued
- Feb 26, 2018
- Abate by
- Jul 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(2): Employer did not install fixed ladders with a minimum perpendicular distance of 7 inches (18 cm) (for elevator pit ladders, a minimum perpendicular distance of 4.5 inches, 11 cm); from the centerline of the steps or rungs, or grab bars, or both, to the nearest permanent object in back of the ladder; Boston Logan International Airport: Employees were exposed to slip and fall hazards while climbing a fixed ladder installed less than seven (7) inches from the nearest permanent object. a. Echo West Baggage Conveyor Room (Terminal E) - clearance in back of fixed ladder for the first rung was approximately 1 inch to a metal raceway attached to the conveyor belt SB-04. b. Baggage Conveyor Room (Terminal B) - clearance on the back of the fixed ladder to the platform that crossed over conveyor belt (ED 4-11) that was used to access the center L3 X-ray Machine was approximately 5.25 inches. The Transportation Security Administration was previously cited for an unsafe/unhealthful working condition of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.27(c)(4), which was contained in OSHA inspection number #885583, notice number 1, item number 4 and was affirmed as a final order on September 3, 2013, with respect to a workplace located at Logan International Airport, Boston, MA.
Recent events (1)
- — Z (R) $0
1910.36 G02
- Issued
- Feb 26, 2018
- Abate by
- Jul 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. Boston Logan International Airport: Aisles and exit accesses were not at least 28 inches in width: a. Air Canada (B-201) Security Checkpoint (Terminal B) - the access between the baggage conveyor and support column where employees traverse to monitor L3 X-ray machine and remove baggage from conveyor, was 24.5 inches. b. Echo West Baggage Conveyor Room (Terminal E) - the access between baggage conveyor ED2-14 and the support column was 13.75 inches. The Transportation Security Administration was previously cited for an unsafe/unhealthful working condition of this occupational safety and health standard or its equivalent standard 29 CFR 1910.36(g)(2), which was contained in OSHA inspection number #885583, notice number 2, item number 1 and was affirmed as a final order on September 3, 2013, with respect to a workplace located at Logan International Airport, Boston, MA.
Recent events (1)
- — Z (R) $0
1910.303 B02
- Issued
- Feb 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Boston Logan International Airport: Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. Echo West Break Area adjacent to Baggage Search (Inspection) Room (Terminal E) - a water cooler, refrigerator, coffee maker and toaster were plugged into a temporary power tap (TPT). b. American Airlines B-5 Break Room (Terminal B) - two (2) toaster ovens were plugged into a TPT. c. Break Room adjacent to B-206 Security Checkpoint (Terminal B) - a refrigerator and a microwave were plugged into a TPT. The Transportation Security Administration was previously cited for an unsafe/unhealthful working condition of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number #885583, notice number 2, item number 6a and was affirmed as a final order on September 3, 2013, with respect to a workplace located at Logan International Airport, Boston, MA.
Recent events (1)
- — Z (R) $0
1910.305 G01 IV A
- Issued
- Feb 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Boston Logan International Airport, Terminal A Break Room: Extension cord was used in lieu of fixed wiring to energize a refrigerator and a microwave. The Transportation Security Administration was previously cited for an unsafe/unhealthful working condition of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number #885583, notice number 2, item number 6b and was affirmed as a final order on September 3, 2013, with respect to a workplace located at Logan International Airport, Boston, MA.
Recent events (1)
- — Z (R) $0
1910.22 A01
- Issued
- Feb 26, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: Boston Logan International Airport, Terminal A: Work areas were not maintained in an orderly, clean, and sanitary condition: a. In Delta Baggage Conveyor Room, Make-Up Area, a fixed stairway to the catwalks used by employees to access the L3 X-ray machines was obstructed by objects in storage. b. Break Room adjacent to the Security Checkpoint was not maintained in a sanitary condition to prevent entrance or harborage of vermin.
Recent events (1)
- — Z (O) $0
More inspections at Transportation Security Administration
View Transportation Security Administration's full OSHA safety record →
More inspections in this industry (NAICS 926120)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342641198.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.