GENEVA, NY —
OSHA Inspection: FINGER LAKES FIBERGLASS, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of FINGER LAKES FIBERGLASS, LLC in 225 LYONS ROAD, GENEVA, NY 14456 (NAICS 326199). OSHA activity number 342641230.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FINGER LAKES FIBERGLASS, LLC
- Site address
- 225 LYONS ROAD
- City
- GENEVA
- State
- NY
- ZIP
- 14456
- Mailing
- 130 HORIZON PARK DRIVE, PENN YAN, NY 14527
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 10
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.106 E06 I
- Issued
- Feb 14, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: a) Production Floor, on or about 9/15/17: Employees dispense the following flammable materials including but not limited to: Resin Polyester C1-3001-23; Acetone and Hetron FR 650 T-20 Resin without grounding the containers.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.106 E06 II
- Issued
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Production Floor, on or about 9/15/17: Employees dispense the following flammable materials from a 55 gallon drum to a secondary container with no means of electrically interconnecting the nozzle and the portable container. Flammable materials include but not limited to: Resin Polyester C1-3001-23; Acetone; Hetron FR 650 T-20 Resin and Flammable Waste.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E02 II B 2
- Issued
- Feb 14, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(b)(2): More than 120 gallons of Category 2, 3, or 4 flammable or combustible liquids in containers were located outside of inside storage room(s) or storage cabinet(s): a) Production Floor, on or about 9/15/17: Storage of Category 2 and 3 flammable materials exceeded 120 gallons, flammable material was approximately 325 gallons located outside if an inside storage room. b) Trimming Department, on or about 9/15/17: Storage of Category 2 and 3 flammable materials exceeded 120 gallons, flammable material was approximately 385 gallons located outside if an inside storage room.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.106 E02 IV D
- Issued
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable or combustible liquids were not drawn from or transferred into vessel(s), container(s), or portable tank(s) within a building through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tank by gravity through an approved self closing valve: a) Production Floor, on or about 9/15/17: Polyester Resin C1 3001-23 a flammable liquid was being dispensed through a non self closing valve.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G02
- Issued
- Feb 14, 2018
- Abate by
- Apr 12, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): Spraying area(s) were not kept free from the accumulation of deposits of combustible residues: a) Production Floor, on or about 9/15/17: There was an accumulation of combustible residues on the mold carts, flammable materials used when manufacturing header molds.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.134 C01
- Issued
- Feb 14, 2018
- Abate by
- Apr 12, 2018
- Penalty
- Initial $1,663 · Current $998 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): Employer did not establish nor implement a written respiratory protection program with worksite specific procedures when respirators were necessary to protect the health of the employee or whenever respirators were required by the employer: a) Production Floor and Trimming Department, on or about 9/15/17: Employer had not established a written respirator protection program when employees were required to wear full face air purifying respirators.
Recent events (2)
- — I (S) $997.8
- — Z (S) $1663
1910.134 F02
- Issued
- Feb 14, 2018
- Abate by
- Apr 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employer did not ensure that an employee using a tight fitting face piece respirator was fit tested prior to initial use of the respirator, whenever a different respirator face piece (size, style, model or make) was used, and at least annually thereafter: a) Production Floor and Trimming Department, on or about 9/15/17: Employees required to wear full face air purifying respirators had not been fit tested.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Feb 14, 2018
- Abate by
- Apr 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k) The employer did not provide effective, comprehensive, understandable, and annual (or more often if necessary) training to employees who are required to use respirators: a) Production Floor and Trimming Department, on or about 9/15/17: Employees are required to wear full face air purifying respirators and had not received respirator training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01
- Issued
- Feb 14, 2018
- Abate by
- Apr 12, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Production Floor, on or about 9/15/17: Powered industrial truck operator was not provided with training.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.1200 E01
- Issued
- Feb 14, 2018
- Abate by
- Apr 12, 2018
- Penalty
- Initial $1,663 · Current $998 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: 1) Labeling and other forms of warning; 2) SDS requirements for the hazardous materials known to be present at the jobsite; 3) Employee training and information. The written program must also include: (a) A list of all the chemicals used at the jobsite. (b) Methods to inform employees of hazards associated with non-routine tasks. (c) Methods the employer will use to inform any contractors employees of workplace hazards. a) Production Floor, on or about 9/15/17: A written hazard communication program was not developed for the employees who work with hazardous materials including but not limited to: Ford Glacier White Ultra Plus; Polyester Resin C1 3001-23; Hetron FR 650 T-20 Resin Luperox DDM-9 Organic Peroxide and Acetone.
Recent events (2)
- — I (S) $997.8
- — Z (S) $1663
More inspections in this industry (NAICS 326199)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342641230.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.