Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: L A STONE & KITCHENS, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of L A STONE & KITCHENS, LLC. in 2053 S.R. 209, BRODHEADSVILLE, PA 18322 (NAICS 327991). OSHA activity number 342647500.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch L a Stone & Kitchens, LLC. — free Get an email when a new federal OSHA severe-injury report for L a Stone & Kitchens, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
2053 S.R. 209
City
BRODHEADSVILLE
State
PA
ZIP
18322
Mailing
2053 S.R. 209, BRODHEADSVILLE, PA 18322
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
5
Ownership type
A

7 citations on file for this inspection.

1910.178 A04

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 27, 2017
Abate by
Dec 28, 2017
Penalty
Initial $1,630 · Current $1,223 Reduced
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval.    a) Facility, 2053 S.R. 209 Brodheadsville, PA - Employees operated the Mitsubishi Caterpillar Forklift LP Model 25N (Serial No. C-459109) with an front-end attached Abaco Forklift Boom Model AFJ-25 (Serial No. 0200812002) without the manufacturer's prior written approval exposing employees to struck-by hazards created by the modifications to the powered industrial truck's lifting capacity and center of gravity, on or about September 19, 2017.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
  • — I (S) $1222.5
  • — Z (S) $1630

1910.178 A05

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 27, 2017
Abate by
Dec 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered.    a) Facility, 2053 S.R. 209 Brodheadsville, PA - Employees operated a Mitsubishi Caterpillar Forklift LP Model 25N (Serial No. C-459109) with an attached Forklift Boom Model AFJ-25 (Serial No. 0200812002) to lift stone slabs on a daily basis. The forklift lacked allowable attachment markings which exposed employees to fall hazards and struck-by hazards due to the unknown modifications to the forklift's lifting capacity and center of gravity created by the use of a front-end attachment, on or about September 19, 2017.    In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A06

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 27, 2017
Abate by
Dec 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition.    a) Facility, 2053 S.R. 209 Brodheadsville, PA - Employees operated a Mitsubishi Caterpillar Forklift LP Model 25N (Serial No. C-459109) to lift materials (stone slabs, pallets, etc.). The forklift's nameplate had an illegible load rating chart exposing employees to fall hazards and struck-by hazards due to unknown load capacities, on or about September 19, 2017.    In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 27, 2017
Abate by
Dec 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    a) Facility, 2053 S.R. 209 Brodheadsville, PA - Employees operated a Mitsubishi Caterpillar Forklift LP Model 25N (Serial No. C-459109) with a front-end attached Abaco Forklift Boom Model AFJ-25 (Serial No. 0200812002) to lift stone slabs without having received documented/certified formal instruction, practical training, and/or operator evaluation thereby exposing employees to fall hazards and struck-by hazards, on or about September 19, 2017.    In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E03

Other-than-serious 1 instance 2 exposed
Issued
Oct 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a) Grinding/Polishing Room, 2053 S.R. 209, Brodheadsville, PA - Two (2) Amerex 10 LB Multi-Purpose Dry Chemical Fire Extinguishers had not received an annual maintenance check since August 2012 (one (1) of which was partially charged) and employees who attempted to extinguish a fire with the portable fire extinguisher were exposed to fire hazards, on or about September 19, 2017.  In accordance with 29 CFR 1903.19, abatement certification is not required for the violation. The hazardous condition was corrected during the inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 C04

Other-than-serious 1 instance 2 exposed
Issued
Oct 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface.   a) South Wall, Grinding/Polishing Room, 2053 Route 209, Brodheadsville, PA - The flush-mounted snap switch (light switch) that operated fluorescent lights had energized conductors that were uncovered due to a missing faceplate, exposing employees to a contact with electrical current hazard, as observed on September 19, 2017.  In accordance with 29 CFR 1903.19, abatement certification is not required for the violation. The hazardous condition was corrected during the inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 J02 IV

Other-than-serious 1 instance 2 exposed
Issued
Oct 27, 2017
Abate by
Nov 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location.  a) North and East Walls, Grinding/Polishing Room, 2053 Route 209, Brodheadsville, PA - Employees used energized receptacles that were not rated for use in a wet or damp location to power electrical equipment (grinders and/or routers) that used water dust suppression systems exposing the employees to contact with electrical current hazards, on or about September 19, 2017.  In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View L a Stone & Kitchens, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342647500.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.