OSHA Inspection: MARIK SPRING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MARIK SPRING, INC. in 121 NORTHEAST AVE., TALLMADGE, OH 44278 (NAICS 332611). OSHA activity number 342651700.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marik Spring, INC. — free Get an email when a new federal OSHA severe-injury report for Marik Spring, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MARIK SPRING, INC.
Site address
121 NORTHEAST AVE.
City
TALLMADGE
State
OH
ZIP
44278
Mailing
121 NORTHEAST AVE., TALLMADGE, OH 44278
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332611
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.215 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 7, 2018
Abate by
Mar 6, 2018
Penalty
Initial $4,398 · Current $3,848 Reduced
29 CFR 1910.215(c)(1): Abrasive wheel(s) used on grinding machinery were not mounted between flanges which were less than one third the diameter of the wheel:    On or about 12/15/2017, the inside diameter (ID) grinder located in the grinding department was not equipped with flanges.  Employees tasked with completing finishing activities on custom/specialty ordered springs were potentially exposed to hazards created by the unguarded projection bit/stud of the abrasive wheel machinery.
Recent events (2)
  • — I (S) $3848
  • — Z (S) $4398

1910.215 C01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 7, 2018
Abate by
Mar 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(c)(1)(ii): Type 1 cutting-off wheels were not mounted between properly relieved flanges which have matching bearing surfaces. Such flanges were not at least one-fourth the wheel diameter:   On or about 12/15/2017, the company's cut-off wheel was inadequately guarded in that it was not equipped with proper flanges.  Employees who use the cut-off wheel during the production of (heavy gauge) metal springs were potentially exposed to struck-by hazards created from flying debris if the abrasive wheel were to explode/shatter and/or disintegrate and become a projectile.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Feb 7, 2018
Penalty
Initial $3,298 · Current $0 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:            On or about 12/05/2017, a metal junction box located in the straight and cut coiling machine area was not installed according to the listing and labeling.  The box was not mounted to a fixed surface.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3298

1910.303 B07 I

Other-than-serious 11 instances 1 exposed
Issued
Feb 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  On or about 12/15/2017, the employer failed to ensure that a junction box used as a power source by employees who operated the company's pedestal grinder was free from damage. The housing was missing a cover (knock out) and thus potential exposed the operator(s) to electrical hazards from the wiring contained within the unit. Energy sources used at the facility include but are not limited to: Electric -110, 220 volt single phase, 220 - 440/480 volt 3 phase and pneumatic energy.