GARDNER, MA —
OSHA Inspection: TERRATHERM, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TERRATHERM, INC. in 151 SUFFOLK LANE, GARDNER, MA 01440 (NAICS 562910). OSHA activity number 342655693.
Where did this inspection happen?
- Establishment
- TERRATHERM, INC.
- Site address
- 151 SUFFOLK LANE
- City
- GARDNER
- State
- MA
- ZIP
- 01440
- Mailing
- 151 SUFFOLK LANE, GARDNER, MA 01440
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- Employees
- 76
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $9054.00 · Current $4527.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to struck by hazards while pressure testing PVC pipe. In the facility at 151 Suffolk Lane Gardner, MA 01440 on 9/21/2017 an employee was exposed to struck by hazards: (a) When he pressure tested PVC pipe using pneumatic testing instead of hydrostatic testing. (b) When he assembled PVC pipe which had solvent cemented joints which were not free of foreign materials (i.e. they were painted). Among other methods, feasible and acceptable means of abatement include, but are not limited to: ASME B31.3-2016, Section A345.5.2, Other Requirements, refrain from pneumatically testing PVC pipe and perform a hydraulic test in accordance with Section A345.4. ASTM D2855-96 section 7.4, Cleaning, when assembling PVC piping systems properly clean surfaces to be joined and remove all foreign material from the pipe surface, including paint. Cleaning methods include chemical and/or mechanical cleaning.
Recent events (3)
- — F (S) $4527
- — C (S) $9054
- — Z (S) $9054
More inspections at TERRATHERM, INC.
FITCHBURG, MA—2009-02-27 00:00:00
TERRATHERM INC.
View TERRATHERM, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562910)
DEER PARK, TX—2026-07-07
HPC INDUSTRIAL SERVICES, LLC
REDMOND, OR—2026-07-02
317744683 - ALPINE ABATEMENT ASSOCIATES INC
FISHER, IL—2026-07-02
ECO WASH LLC
BEND, OR—2026-06-30
317744684 - ALPINE ABATEMENT ASSOCIATES INC
MILL VALLEY, CA—2026-06-30
AXELSON BUILDERS INC
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342655693.