BETHEL, PA —
OSHA Inspection: SINGH & KAUR INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SINGH & KAUR INC in 351 MIDWAY ROAD, BETHEL, PA 19507 (NAICS 811192). OSHA activity number 342657780.
Where did this inspection happen?
- Establishment
- SINGH & KAUR INC
- Site address
- 351 MIDWAY ROAD
- City
- BETHEL
- State
- PA
- ZIP
- 19507
- Mailing
- 351 MIDWAY ROAD, BETHEL, PA 19507
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811192
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 A02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition: (a) TRUCK WASH GARAGE/MOTOR ROOM - Employees performed truck washing duties in the wash garage, and the floors of the garage and motor room contained multiple slip and trip hazards, including hoses and puddles of water, which thereby exposed employees to possible injuries, on or about September 20, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $2716.00
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) TRUCK WASH BUILDING - Employees washed trucks in the truck wash building using WAB branded products including but not limited to Ultimate Truck Wash (Sodium DDBSA), Aluminum Trailer Cleaner-Restorer (Sulfuric Acid, Hydrogen Fluoride, Phosphoric Acid, Glycol Ether), and Polished Aluminum and Stainless Cleaner (Phosphoric Acid, Glycol Ether), and the employer had not provided a means for flushing the eyes, which thereby exposed employees to possible injuries, on or about September 20, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2716
1910.303 C03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(c)(3)(i): Splices and joints and free ends were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose: (a) TRUCK WASH GARAGE, MOTOR ROOM - Employees performing work in the motor room area of the truck wash garage were exposed to 110 volt electrical shock hazards when the employer failed to ensure that the electrical conductors attached to the pump motor that had been spliced using wire nuts were protected with insulation equivalent to OEM specifications, on or about September 20, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) TRUCK WASH GARAGE, MOTOR ROOM - Employees performing work in the motor room area of the truck wash garage were exposed to 110 volt electrical shock hazards when the employer failed to ensure that a four inch knockout in the side of the main electrical service panel was not covered, thereby exposing employees to the energized conductors within, on or about September 20, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) TRUCK WASH GARAGE, MOTOR ROOM - Employees performing work in the motor room area of the truck garage were exposed to 110 volt electrical shock hazards when the employer failed to ensure that the junction box on the ceiling of the room was equipped with a cover, which allowed multiple energized conductors to hang out of the box, on or about September 20, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1910.305 C04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface: (a) TRUCK WASH GARAGE, MOTOR ROOM - Employees performing work in the motor room area of the truck wash garage were exposed to 110 volt electrical shock hazards when the employer failed to ensure that the light switch on the North wall of the room was equipped with a cover plate, on or about September 20, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $2716.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) TRUCK WASH BUILDING - Employees washed trucks in the truck wash building using WAB branded products including but not limited to Ultimate Truck Wash (Sodium DDBSA), Aluminum Trailer Cleaner-Restorer (Sulfuric Acid, Hydrogen Fluoride, Phosphoric Acid, Glycol Ether), and Polished Aluminum and Stainless Cleaner (Phosphoric Acid, Glycol Ether), and the employer had not developed and implemented a written hazard communication program, which thereby exposed employees to possible injuries, on or about September 20, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2716
1910.1200 F06 II
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $2716.00
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: (a) TRUCK WASH BUILDING - Employees washed trucks in the truck wash building, and the employer had not ensured that at least two 55 gallon barrels of products used for cleaning trucks, including WAB Aluminum Trailer Cleaner-Restorer (Sulfuric Acid, Hydrogen Fluoride, Phosphoric Acid, Glycol Ether), and general Armor-all cleaner(mineral spirits) had identification labels attached to the container, which thereby exposed employees to possible injuries, on or about September 20, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2716
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $2716.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area: (a) TRUCK WASH BUILDING - Employees working in the truck wash area were not provided training on the chemicals that they work with, including but not limited to WAB Ultimate Truck Wash (Sodium DDBSA), WAB Aluminum Trailer Cleaner-Restorer (Sulfuric Acid, Hydrogen Fluoride, Phosphoric Acid, Glycol Ether), and WAB Polished Aluminum and Stainless Cleaner (Phosphoric Acid, Glycol Ether), which thereby exposed employees to possible injuries, on or about September 20, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2716
More inspections at SINGH & KAUR INC
LAKE HOPATCONG, NJ—2014-11-13 00:00:00
SINGH & KAUR INC.
LAKE HOPATCONG, NJ—2014-04-23 00:00:00
SINGH & KAUR INC.
View SINGH & KAUR INC's full OSHA safety record →
More inspections in this industry (NAICS 811192)
VANCOUVER, WA—2026-06-30
WA317991867 - KAADY CHARLES M
EVERETT, WA—2026-06-25
WA317991829 - GREEN MELON LLC
LAS VEGAS, NV—2026-06-17
UNCLE RAYSKI'S MAGIC CAR WASH RIDE LLC
SUTTON, MA—2026-06-10
MICKEY'S CAR WASH & DETAIL SHOP
NASHVILLE, TN—2026-06-10
TAKE 5 CAR WASH
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.