Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VICTORIA'S ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VICTORIA'S ROOFING in 4330 HAVEN COURT, OSHKOSH, WI 54904 (NAICS 238160). OSHA activity number 342662806.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Victoria'S Roofing — free Get an email when a new federal OSHA severe-injury report for Victoria'S Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
VICTORIA'S ROOFING
Site address
4330 HAVEN COURT
City
OSHKOSH
State
WI
ZIP
54904
Mailing
954 BETTY AVE, NEENAH, WI 54956
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Deleted Serious Gravity 5 3 instances 3 exposed
Issued
Dec 20, 2017
Abate by
Dec 29, 2017
Penalty
Initial $1,956 · Current $0 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502:  On or about September 25, 2017 three employees were exposed to fall hazards from 9-10 feet while installing roofing shingles without fall protection on a new construction residential home.
Recent events (3)
  • — R (S) $0
  • — C (S) $1956
  • — Z (S) $1956

1926.1053 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Dec 20, 2017
Abate by
Dec 29, 2017
Penalty
Initial $1,956 · Current $0 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:  On or about September 25, 2017 the portable extension ladder, used to access the roof level was not extended three feet above the roof level.
Recent events (3)
  • — R (S) $0
  • — C (S) $1956
  • — Z (S) $1956

View Victoria'S Roofing's full OSHA safety record →