On , OSHA opened a federal Agency safety inspection of MICHAEL FOODS, INC. in 105 NORTH MAIN, WAKEFIELD, NE 68784 (NAICS 311999). OSHA activity number 342663499.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Michael Foods, INC. — free Get an email when a new federal OSHA severe-injury report for Michael Foods, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MICHAEL FOODS, INC.
Site address
105 NORTH MAIN
City
WAKEFIELD
State
NE
ZIP
68784
Mailing
105 NORTH MAIN, WAKEFIELD, NE 68784
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
320
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 10 1 instance 11 exposed
Issued
Mar 15, 2018
Abate by
Nov 27, 2018
Penalty
Initial $12,934 · Current $9,054 Reduced
29 CFR 1910.147(c)(4)(ii)(B):  The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:     The employer is failing to protect employees from struck by and crushing hazards associated with servicing and maintaining equipment with stored energy.  This was most recently documented on September 27, 2017 during the inspection of the facility located at 105 N. Main St. Wakefield, NE; where the employer has developed inadequate written specific procedures for the Poweramp VS Series 66 Dock Levelers.  The procedures do not identify hydraulic and gravity as potential sources of stored energy nor do they provide instruction on methods to relieve and block those sources of energy.
Recent events (3)
  • — F (S) $9054
  • — C (S) $12934
  • — Z (S) $12934

1910.147 C07 I

Serious Gravity 10 3 instances 9 exposed
Issued
Mar 15, 2018
Abate by
Nov 27, 2018
Penalty
Initial $12,934 · Current $9,054 Reduced
29 CFR 1910.147(c)(7)(i):  The employer did not provide adequate training to ensure that employees had the knowledge and skills required for the safe application, usage and removal of energy control devices:     The employer is failing to train employees on the struck by and crushing hazards associated with servicing and maintaining equipment with stored energy.  This was most recently documented on September 27, 2017 during the inspection of the facility located at 105 N. Main St. Wakefield, NE; where the employer has inadequately trained employees operating, troubleshooting and repairing equipment such as but not limited to dock levelers.
Recent events (3)
  • — F (S) $9054
  • — C (S) $12934
  • — Z (S) $12934

1910.147 D05 I

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 15, 2018
Abate by
Nov 27, 2018
Penalty
Initial $12,934 · Current $9,054 Reduced
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices    The employer is failing to protect employees from struck by and crushing hazards associated with servicing and maintaining equipment with stored energy.  The most recent occurrence of this was evident on September 27, 2017 during the inspection of the facility located at 105 N. Main St. Wakefield, NE; where the employer has employees maintaining and servicing dock levelers without using the manufactured designed and installed maintenance prop as means of isolating the gravity and hydraulic crushing hazards which lead to the death of an employee on September 26, 2017.
Recent events (3)
  • — F (S) $9054
  • — C (S) $12934
  • — Z (S) $12934

1910.303 B01 VIII

Serious Gravity 5 3 instances 2 exposed
Issued
Mar 15, 2018
Abate by
Nov 27, 2018
Penalty
Initial $10,163 · Current $6,651 Reduced
29 CFR 1910.303(b)(1)(viii):  The employer did not ensure that electrical equipment was free from recognized hazards, based on the safeguarding of persons using or likely to come in contact with equipment:   The employer is failing to protect employees from 480 volt electrical and arc flash hazards associated with working in the vicinity of unsecured enclosure doors.  This was most recently documented on September 27, 2017 during the inspection of the facility located at 105 N. Main St. Wakefield, NE; where the employer has employees exposed to unsecured enclosure doors in electrical room 81.  Electrical installations in the room have doors which are not secured allowing them to open freely which exposes personnel in the area to live parts and possible arc flash hazards.
Recent events (3)
  • — F (S) $6651
  • — C (S) $10163
  • — Z (S) $10163

1910.305 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 15, 2018
Abate by
Nov 27, 2018
Penalty
Initial $10,163 · Current $6,651 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:          The employer is failing to protect employees from electrical hazards associated to accessing ineffectively protected electrical cabinets.  This was most recently documented on September 27, 2017 during the inspection of the facility located at 105 N. Main St. Wakefield, NE; where the employer has employees accessing electrical panels A24 and A8 to de-energize equipment and the openings within the cabinet are not effectively closed due to missing front blank adapters.
Recent events (3)
  • — F (S) $6651
  • — C (S) $10163
  • — Z (S) $10163

1910.147 C06 I

Repeat Gravity 10 1 instance 10 exposed
Issued
Mar 15, 2018
Abate by
Nov 27, 2018
Penalty
Initial $129,336 · Current $90,536 Reduced
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    The employer is failing to protect employees from all hazards associated with authorized employees performing service and maintenance of equipment with stored energy. The most recent occurrence of this was documented on September 27, 2017 during the inspection of the facility located at 105 N. Main St. Wakefield, NE; where the employer failed to conduct the annual periodic review of the written lockout tagout procedures for all equipment at its Wakefield facility, including, but not limited to, the Poweramp VS Series 66 Dock Levelers numbers 1-6 located in the cold storage load warehouse.
Recent events (3)
  • — F (R) $90536
  • — C (W) $129336
  • — Z (W) $129336

View Michael Foods, INC.'s full OSHA safety record →