Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KLM FRAMING LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of KLM FRAMING LLC in 3063 BRIGHTON BLVD, DENVER, CO 80216 (NAICS 238130). OSHA activity number 342667177.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KLM Framing LLC — free Get an email when a new federal OSHA severe-injury report for KLM Framing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
KLM FRAMING LLC
Site address
3063 BRIGHTON BLVD
City
DENVER
State
CO
ZIP
80216
Mailing
13186 E. LINVALE PL., AURORA, CO 80014
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
20
Ownership type
A

3 citations on file for this inspection.

1926.451 G01 II

Other-than-serious 1 instance 1 exposed
Issued
Nov 2, 2017
Abate by
Dec 7, 2017
Penalty
Initial $1,847 · Current $1,200 Reduced
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system:    (a) KLM Framing LLC at 3063 Brighton Blvd, Denver, CO 80216: On and before September 26, 2017 the exposing employer did not ensure that each employee engaged in window installation from a Spider Rolling Gantry with 5x5 Outrigger on the eighth floor of a high-rise apartment building at a height of approximately 55 feet was protected by a guard rail system. An employee hung from the side and guardrail of a two-point suspension scaffold, while wearing an independent personal fall arrest system, to install a window, where the scaffold did not provide access.  During these activities the employee was not protected by a guardrail system and the employee was potentially exposed to hazards associated with fall arrest and suspension trauma.
Recent events (2)
  • — I (O) $1200
  • — Z (S) $1847

1926.454 A

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 2, 2017
Abate by
Dec 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  (a) KLM Framing LLC at 3063 Brighton Blvd, Denver, CO 80216: On and before September 26, 2017 the exposing employer did not ensure that each employee engaged in window installation from a Spider Rolling Gantry with 5x5 Outrigger on the eighth floor of a high-rise apartment building at a height of approximately 55 feet was trained to recognize the hazards associated with a two-point suspension scaffold and to understand the procedures to control or minimize those hazards. An employee hung from the side and guardrail of a two-point suspension scaffold, while wearing an independent fall arrest system, to install a window, where the scaffold did not provide access. This condition potentially exposed the employee to hazards associated with fall arrest and suspension trauma.     Abatement Note: The training shall include the following areas, as applicable: 1. The nature of any electrical hazards, fall hazards and falling object hazards in the work area; 2. The correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection systems and falling object protection systems being used; 3. The proper use of the scaffold, and the proper handling of materials on the scaffold; 4. The maximum intended load and the load-carrying capacities of the scaffolds used; and 5. Any other pertinent requirements of this subpart.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Nov 2, 2017
Abate by
Dec 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  (a) KLM Framing LLC at 3063 Brighton Blvd, Denver, CO 80216: On and before September 26, 2017 the exposing employer did not ensure that each employee engaged in window installation from a Spider Rolling Gantry with 5x5 Outrigger on the eighth floor of a high-rise apartment building at a height of approximately 55 feet was trained to recognize the hazards of working at elevation and trained in the use of fall protection. An employee hung from the side and guardrail of a two-point suspension scaffold, while wearing an independent fall arrest system, to install a window, where the scaffold did not provide access. This condition potentially exposed the employee to hazards associated with fall arrest and suspension trauma.   Abatement Note: The employer shall assure that each employee has been trained, as necessary, by a competent person qualified in the following areas: 1) The nature of fall hazards in the work area; 2) The correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used; 3) The use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used;  4) The role of each employee in the safety monitoring system when this system is used; 5) The limitations on the use of mechanical equipment during the performance of roofing work on low-sloped roofs; 6) The correct procedures for the handling and storage of equipment and materials and the erection of overhead protection; and 7) The role of employees in fall protection plans; 8) The standards contained in this subpart.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View KLM Framing LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342667177.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.