CONYERS, GA —
OSHA Inspection: FREY-MOSS STRUCTURES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FREY-MOSS STRUCTURES, INC. in 1801 ROCKDALE INDUSTRIAL BLVD., CONYERS, GA 30012 (NAICS 321992). OSHA activity number 342667896.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FREY-MOSS STRUCTURES, INC.
- Site address
- 1801 ROCKDALE INDUSTRIAL BLVD.
- City
- CONYERS
- State
- GA
- ZIP
- 30012
- Mailing
- 1801 ROCKDALE INDUSTRIAL BLVD., CONYERS, GA 30012
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321992
- Employees
- 55
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Dec 7, 2017
- Abate by
- Jan 4, 2018
- Penalty
- Initial $3,232 · Current $1,939 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a. 1801 Rockdale Industrial Blvd, Conyers, GA - On or about 09/28/17, Maintenance employees were exposed to sudden energization or start-up of multi-energy source equipment/machinery such as, but not limited to the Accupress, Press Brake, CNC and Bradbury Stock Reel. The company's written lockout/tagout specific procedures were found with the following deficiencies: 1. The energy control procedures did not properly identify the energy source and/or how to relieve the pneumatic stored energy source that was identified and/or listed on the equipment. 2. The energy control procedures did not specifically outline the steps for the removal of locks and restoring lockout/tagout equipment back into services.
Recent events (2)
- — I (S) $1939.2
- — Z (S) $3232
1910.212 A03 I
- Issued
- Dec 7, 2017
- Abate by
- Jan 4, 2018
- Penalty
- Initial $8,873 · Current $5,324 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. 1801 Rockdale Industrial Blvd, Conyers, GA (Accurshear Machine) - Employees were exposed to struck-by/caught-between hazard. The guard bars/rails on the Shear Machine was inadequate. The guard did not completely enclose the hold down cylinders, which holds the metal pieces in place. There was a opening approximately one-inch wide enough for employees to get their hands under the guard bars, causing a struck-by and/or caught-between hazard, on or about 09/28/17.
Recent events (2)
- — I (S) $5323.8
- — Z (S) $8873
More inspections at Frey-Moss Structures, INC.
View Frey-Moss Structures, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321992)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342667896.