LEBANON, NH —
OSHA Inspection: KLEEN LAUNDRY AND DRYCLEANING SERVICES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KLEEN LAUNDRY AND DRYCLEANING SERVICES in 1 FOUNDRY STREET, LEBANON, NH 03766 (NAICS 812320). OSHA activity number 342690575.
Where did this inspection happen?
- Establishment
- KLEEN LAUNDRY AND DRYCLEANING SERVICES
- Site address
- 1 FOUNDRY STREET
- City
- LEBANON
- State
- NH
- ZIP
- 03766
- Mailing
- 1 FOUNDRY STREET, LEBANON, NH 03766
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812320
- Employees
- 100
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.25 B01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $1455.00 Reduced
General-duty citation text
29 CFR 1910.25(b)(1): The employer did not ensure handrails, stair rail systems, and guardrail systems were provided in accordance with 29 CFR 1910.28: a. Washroom - On or about October 5, 2017, handrails were not provided at the emergency exit staircase.
Recent events (2)
- — I (S) $1455
- — Z (S) $3880
1910.36 H01
- Issued
- Abate by
- Penalty
- Initial $5174.00 · Current $1940.00 Reduced
General-duty citation text
29 CFR 1910.36(h)(1): The outside exit route did not have guardrails to protect from a fall hazard: a. Washroom - On or about October 5, 2017, the exterior emergency exit platform was not provided with guardrails to prevent employee falls of over 4 feet.
Recent events (2)
- — I (S) $1940
- — Z (S) $5174
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $5174.00 · Current $1940.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Stairs or a ramp were not provided where the exit route was not substantially level: a. Washroom - On or about October 5, 2017, the exterior emergency exit was not provided with stairs or a ramp where the break of elevation was over 3 feet.
Recent events (2)
- — I (S) $1940
- — Z (S) $5174
1910.37 A04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: Instance a. Dry-cleaning building - On or about October 5, 2017, the emergency exit lighting was not maintained, in that the lighting system was not working. Instance b. Storage building - On or about October 5, 2017, the emergency exit lighting was not maintained, in that the lighting system was not working. Instance c. Storage building - On or about October 5, 2017, the emergency fire pull station was completely dismantled and not available for use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(2): The exits in the area were not marked with a sign reading "Exit": a. Office - On or about October 5, 2017, the emergency exit was not provided with signage indicating it was an emergency exit.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and was not distinctive in color: Instance a. Dry-cleaning building - On or about October 5, 2017, the emergency exit sign was not maintained, in that the signage was not illuminated. Instance b. Storage building - On or about October 5, 2017, the emergency exit sign was not maintained, in that the signage was not illuminated.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $6467.00 · Current $2425.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where the eyes of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes were not available for immediate emergency use: a. Dry-cleaning building - On or about October 5, 2017, the (Bradley) emergency eye wash station was not maintained, in that it was disabled and not available for emergency use.
Recent events (2)
- — I (S) $2425
- — Z (S) $6467
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(3) At this establishment, portable fire extinguishers had not been subjected to an annual maintenance check: Instance a. Dry-cleaning building - On or about October 5, 2017, annual inspections were not performed on the fire extinguisher in use which was last inspected on February of 2009. Instance b. Storage building - On or about October 5, 2017, annual inspections were not performed on the fire extinguisher in use which was last inspected on May of 2014. Instance c. Warehouse building - On or about October 5, 2017, annual inspections were not performed on the fire extinguisher in use which was last inspected on May of 2015.
Recent events (2)
- — I (O) $0
- — Z (S) $3880
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $9054.00 · Current $2587.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation guards were not designed and constructed to prevent the operator from having any part of his/ her body in the danger zone during the operating cycle: a. Blanket machine - On or about October 5, 2017, the Chicago Edge Automatic Feeder (blanket machine), was not adequately guarded, in that the machine guarding sensors did not operate when engaged.
Recent events (2)
- — I (S) $2587
- — Z (S) $9054
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listed or labeling: a. Warehouse building - On or about October 5, 2017, the electrical receptacle box knockout box was used in a purpose of which was not designed, in that the box was used in a pendulum installation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment: Instance a. Dry-cleaning building - On or about October 5, 2017, the building's electrical panels PP2 and PP2-1, were blocked with trash and debris and were not adequately accessible during maintenance or emergency events. Instance b. Supply closet - On or about October 5, 2017, the electrical panels were blocked with trash and debris and were not adequately accessible during maintenance or emergency events.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 812320)
ADJUNTAS, PR—2026-07-09
NICK A VAZQUEZ TORRES
LAUREL, MD—2026-07-08
ZIPS CLEANERS
COLLEGE PARK, MD—2026-07-08
PASHAK CLEANERS LLC
BAYAMON, PR—2026-06-29
EDWARD MORALES MENDEZ
YAUCO, PR—2026-06-29
CUATRO CALLES DRY CLEANERS INC
More inspections in NH
PORTSMOUTH, NH—2026-07-15
RODAS CONSTRUCTION CORP
DOVER, NH—2026-07-15
KNOX MARSH DEVELOPMENT LLC
DOVER, NH—2026-07-15
REAL PRO BUILDERS CONSTRUCTION INC
MERRIMACK, NH—2026-07-15
BURGER KING
MILFORD, NH—2026-07-15
R G EXTERIORS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342690575.