OSHA Inspection: F-S PRESTRESS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of F-S PRESTRESS, LLC in 7284 HIGHWAY 49 N., HATTIESBURG, MS 39404 (NAICS 327390). OSHA activity number 342690666.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch F-S Prestress, LLC — free Get an email when a new federal OSHA severe-injury report for F-S Prestress, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
F-S PRESTRESS, LLC
Site address
7284 HIGHWAY 49 N.
City
HATTIESBURG
State
MS
ZIP
39404
Mailing
PO BOX 15969, HATTIESBURG, MS 39404
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
86
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 5 instances 3 exposed
Issued
Jan 10, 2018
Penalty
Initial $4,205 · Current $2,523 Reduced
OSH ACT of 1970 Section (5)(a)(1): Public Law 91-596, the Occupational Safety and Health Act of 1970, Section 5(a)(1): The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or are likely to cause death or serious physical harm to his employees, in that employees were exposed to: An impalement hazard. The rebar storage rack legs were not guarded to prevent impalement.   a. Fabrication - On or about October 5, 2017 The rebar storage rack legs were not guarded to prevent impalement.
Recent events (2)
  • — I (S) $2523
  • — Z (S) $4205

1910.22 A03

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 10, 2018
Penalty
Initial $2,523 · Current $1,514 Reduced
29 CFR 1910.22(a)(3): Walking-working surfaces were not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice:  a. Maintenance and Fabrication - On or about October 5, 2017 an air hose and an extension cord was stretched across the maintenance shop floor.  The air hose had a loop that projected above the floor and created a  trip hazard. Scrap pieces of rebar were laying on the ground outside of the fabrication building next to the rebar storage racks and the power cords for the bender and chop saw inside fabrication created a trip hazard.
Recent events (2)
  • — I (S) $1513.8
  • — Z (S) $2523

1910.212 A03 II

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 10, 2018
Abate by
Jan 26, 2018
Penalty
Initial $2,968 · Current $1,781 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s)  a. Fabrication - On or about October 5, 2017 the adjustable guard was missing from the Dewalt chop saw used to cut rebar and metal conduit.
Recent events (2)
  • — I (S) $1780.8
  • — Z (S) $2968

1910.184 F01

Other-than-serious 3 instances 20 exposed
Issued
Jan 10, 2018
Abate by
Jan 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.184(f)(1): Wire-rope slings did not  have permanently affixed and legible identification markings as prescribed by the manufacturer  that indicated the recommended safe working load for the type(s) of hitch(es) used, the angle upon which it is based, and the number of legs if more than one.   a. Mi-Jack 50 Travelift Gantry Crane - On or about October 6, 2017 the wire rope slings for the Mi-Jack 50 Travelift gantry crane did not have identification tags or markings that stated the lifting capacity.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Jan 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  a. Fabrication - On or about October 5, 2017 a microwave oven was plugged into a relocatable power tap; and the relocatable power tap was plugged into an extension cord that was plugged into a wall receptacle.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Jan 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.  a. Maintenance Shop - On or about October 5, 2017 an extension cord that was wrapped around the box fan handhold did not have strain relief.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View F-S Prestress, LLC's full OSHA safety record →