Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORRIS CYLINDERS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORRIS CYLINDERS in 4818 W LOOP 281, LONGVIEW, TX 75603 (NAICS 332313). OSHA activity number 342692456.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Norris Cylinders — free Get an email when a new federal OSHA severe-injury report for Norris Cylinders is published. One employer, no account, unsubscribe in one click.
Establishment
NORRIS CYLINDERS
Site address
4818 W LOOP 281
City
LONGVIEW
State
TX
ZIP
75603
Mailing
4818 W LOOP 281, LONGVIEW, TX 75603
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
Employees
170
Ownership type
A

3 citations on file for this inspection.

1910.22 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 3, 2017
Abate by
Nov 16, 2017
Penalty
Initial $12,675 · Current $7,605 Reduced
29 CFR 1910.22(a)(1): (1) The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition.  This violation most recently occurred on or about September 30, 2017, where employees such as but not limited to employees working near and with the LS Blaster leaking hydraulic fluid were exposed to a slip hazard.
Recent events (2)
  • — I (S) $7605
  • — Z (S) $12675

1910.147 C07 I B

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 3, 2017
Abate by
Nov 16, 2017
Penalty
Initial $12,675 · Current $7,605 Reduced
29 CFR 1910.147(c)(7)(i)(B):  The employer did not ensure that each affected employee is instructed in the purpose and use of the energy control procedures.  This violation most recently occurred on or about September 30, 2017, where employees such as but not limited to employees working near and with the LS Blaster operator and work in the immediate vicinity of maintenance department employees performing maintenance and/or repair on machinery or equipment such as but not limited to LS Blaster.
Recent events (2)
  • — I (S) $7605
  • — Z (S) $12675

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 3, 2017
Abate by
Nov 16, 2017
Penalty
Initial $12,675 · Current $7,605 Reduced
29 CFR 1910.212(a)(1): The employer did not ensure that one or more methods of machine guarding was provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.   This violation occurred on or about September 30, 2017, when an employee was allowed in an area where trouble shooting was being conducted by the maintenance department and machine guarding had been removed.
Recent events (2)
  • — I (S) $7605
  • — Z (S) $12675

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342692456.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.